Fractional exhaled nitric oxide at multiple flow rates in chronic cough: association with lung function and airway hyperresponsiveness

Background The relationship between airway inflammation and airflow obstruction in patients with chronic cough remains unclear. This study aimed to evaluate the relationships between multi-flow fractional exhaled nitric oxide parameters (FeNO50, FeNO200, and CaNO) and lung function, and to assess their utility in predicting airway hyperresponsiveness (AHR) in this population.Materials and methods This retrospective study enrolled 2205 chronic cough outpatients who underwent spirometry and multiple-flow FeNO measurements. Patients were stratified by airway function and FeNO levels for group comparisons, and Spearman’s rank correlation was used. In a subgroup (n = 582) who underwent methacholine bronchial provocation test (BPT), the diagnostic accuracy of these parameters for AHR was evaluated.Results Among 2014 patients with normal ventilation or airflow obstruction, FeNO50 and FeNO200 were significantly higher in outpatients with airflow obstruction than those with both normal ventilation and normal small airway function (p < 0.01). Weak but significant negative correlations were found between FeNO50 or FeNO200 and lung function parameters (all coefficients ∼0.1), which were slightly stronger in females. FeNO50 and FeNO200 showed moderate diagnostic value (AUCs: 0.775 and 0.721, Cut-off: 31.5 and 14.5 ppb, respectively), while CaNO showed none. Combining FeNO50 with small airway parameter (FEF50%pred) yielded the highest predictive accuracy (AUC: 0.895).Conclusions FeNO50 and FeNO200 are associated with the severity of airflow obstruction and moderately predict AHR in chronic cough, whereas CaNO does not. Combining FeNO with lung function parameters enhances predictive performance. Despite statistical significance, the weak correlations between FeNO and lung function parameters warrant cautious clinical interpretation.

Authors

Institutions

Publication Details

Journal
Annals of Medicine
Published
2026-06-26
DOI
https://doi.org/10.1080/07853890.2026.2681282
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fractional exhaled nitric oxide at multiple flow rates in chronic cough: association with lung function and airway hyperresponsiveness

Yun Liu, Yan Zhang, Dan Wang
Annals of Medicine
Chronic Obstructive Pulmonary Disease (COPD) Research
article

Fractional exhaled nitric oxide at multiple flow rates in chronic cough: association with lung function and airway hyperresponsiveness

Yun Liu, Yan Zhang, Dan Wang
article en

Abstract

Background The relationship between airway inflammation and airflow obstruction in patients with chronic cough remains unclear. This study aimed to evaluate the relationships between multi-flow fractional exhaled nitric oxide parameters (FeNO50, FeNO200, and CaNO) and lung function, and to assess their utility in predicting airway hyperresponsiveness (AHR) in this population.Materials and methods This retrospective study enrolled 2205 chronic cough outpatients who underwent spirometry and multiple-flow FeNO measurements. Patients were stratified by airway function and FeNO levels for group comparisons, and Spearman’s rank correlation was used. In a subgroup (n = 582) who underwent methacholine bronchial provocation test (BPT), the diagnostic accuracy of these parameters for AHR was evaluated.Results Among 2014 patients with normal ventilation or airflow obstruction, FeNO50 and FeNO200 were significantly higher in outpatients with airflow obstruction than those with both normal ventilation and normal small airway function (p < 0.01). Weak but significant negative correlations were found between FeNO50 or FeNO200 and lung function parameters (all coefficients ∼0.1), which were slightly stronger in females. FeNO50 and FeNO200 showed moderate diagnostic value (AUCs: 0.775 and 0.721, Cut-off: 31.5 and 14.5 ppb, respectively), while CaNO showed none. Combining FeNO50 with small airway parameter (FEF50%pred) yielded the highest predictive accuracy (AUC: 0.895).Conclusions FeNO50 and FeNO200 are associated with the severity of airflow obstruction and moderately predict AHR in chronic cough, whereas CaNO does not. Combining FeNO with lung function parameters enhances predictive performance. Despite statistical significance, the weak correlations between FeNO and lung function parameters warrant cautious clinical interpretation.

Annals of MedicineVol. 58(1)
Second Affiliated Hospital of Xi'an Jiaotong University (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 7%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.