Kidney Transplant Function in Recipients from Deceased Donors with COVID-19

Background: During the COVID-19 pandemic, uncertainty regarding the safety of kidneys from COVID-19-positive donors led to a reduction in kidney transplants and increased organ non-use in the United States. This study aims to evaluate whether donor COVID-19 positivity is associated with one-year post-transplant estimated glomerular filtration rate (eGFR) among kidney transplant recipients. Methods: This retrospective cohort study used data from the United States Organ Procurement and Transplantation Network (OPTN) 2020–2024. Donor COVID-19 status was determined by the SARS-CoV-2 nucleic acid amplification technique (NAT) and antibody test results. The main outcome was recipients’ one-year eGFR, estimated by the CKD-EPI 2021 formula. Linear regression models were used to compare the mean one-year eGFR among donor COVID-19 groups, adjusted by inverse probability of treatment weights. Interaction terms of donor acute kidney injury status and race were assessed to evaluate effect modification. Results: Among 38,199 included kidney transplant recipients, 1090 (2.9%) received kidneys from donors with active COVID-19 infection, 423 (1.1%) from donors with resolved infection, and 36,686 (96.0%) from COVID-19-negative donors. After weighting and adjustment, there was no significant difference in one-year eGFR for recipients of kidneys from donors with active COVID-19 (mean difference, 0.05 [95% CI, −1.08 to 1.18]) or resolved infection (mean difference, −0.27 [95% CI, −2.19 to 1.64]) compared with COVID-19-negative donors. Neither donor AKI nor donor race modified the association between donor COVID-19 status and one-year eGFR. Conclusions: This study suggests that kidneys from COVID-19-positive donors may be a viable option without compromising short-term allograft function as measured by 1-year eGFR.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-06-25
DOI
https://doi.org/10.3390/jcm15134955
Primary Topic
COVID-19 Clinical Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Kidney Transplant Function in Recipients from Deceased Donors with COVID-19

Krista L. Lentine, Bekir Tanrıöver, Su‐Hsin Chang, Tarek Alhamad et al.
Journal of Clinical Medicine
COVID-19 Clinical Research Studies
article

Kidney Transplant Function in Recipients from Deceased Donors with COVID-19

Krista L. Lentine, Bekir Tanrıöver, Su‐Hsin Chang, Tarek Alhamad, Siobhan Sutcliffe, Mengmeng Ji, Dema Yaseen Alsabbagh, Massini Merzkani
article en

Abstract

Background: During the COVID-19 pandemic, uncertainty regarding the safety of kidneys from COVID-19-positive donors led to a reduction in kidney transplants and increased organ non-use in the United States. This study aims to evaluate whether donor COVID-19 positivity is associated with one-year post-transplant estimated glomerular filtration rate (eGFR) among kidney transplant recipients. Methods: This retrospective cohort study used data from the United States Organ Procurement and Transplantation Network (OPTN) 2020–2024. Donor COVID-19 status was determined by the SARS-CoV-2 nucleic acid amplification technique (NAT) and antibody test results. The main outcome was recipients’ one-year eGFR, estimated by the CKD-EPI 2021 formula. Linear regression models were used to compare the mean one-year eGFR among donor COVID-19 groups, adjusted by inverse probability of treatment weights. Interaction terms of donor acute kidney injury status and race were assessed to evaluate effect modification. Results: Among 38,199 included kidney transplant recipients, 1090 (2.9%) received kidneys from donors with active COVID-19 infection, 423 (1.1%) from donors with resolved infection, and 36,686 (96.0%) from COVID-19-negative donors. After weighting and adjustment, there was no significant difference in one-year eGFR for recipients of kidneys from donors with active COVID-19 (mean difference, 0.05 [95% CI, −1.08 to 1.18]) or resolved infection (mean difference, −0.27 [95% CI, −2.19 to 1.64]) compared with COVID-19-negative donors. Neither donor AKI nor donor race modified the association between donor COVID-19 status and one-year eGFR. Conclusions: This study suggests that kidneys from COVID-19-positive donors may be a viable option without compromising short-term allograft function as measured by 1-year eGFR.

Journal of Clinical MedicineVol. 15(13)
University of Arizona (US), Washington University in St. Louis (US), Saint Louis University (US)
Good health and well-being
Openalex Percentile: Top 7%
COVID-19 Clinical Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.