New insights in primary aldosteronism diagnosis: a prospective multicenter study

OBJECTIVES: The high variability in screening and confirmatory cut-off values for primary aldosteronism (PA) largely reflects the insufficient standardization of current analytical methods. Competitive and sandwich immunoassays show variable correlation with the reference liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique. This prospective multicenter study aimed to establish diagnostic thresholds for PA using a novel sandwich immunoassay. METHODS: A total of 676 patients suspected of PA were consecutively enrolled from 7 medical centers in China. All participants underwent a captopril challenge test (CCT), followed by a seated saline infusion test (sSIT) on the third day. Plasma aldosterone concentration (PAC) and plasma renin concentration (PRC) were measured using a fully automated chemiluminescent immunoassay platform (Maglumi X8, SNIBE, China). PA was diagnosed according to current clinical guidelines. RESULTS: An aldosterone renin ratio (ARR) cut-off of 11 ng/L/mU/L showed 90 % sensitivity (95 % CI: 85-94 %) and 62 % specificity (95 % CI: 58-67 %) with the area under the receiver-operator characteristic curves (AUC) of 0.843 (95 % CI: 0.81-0.87). PAC post-sSIT and PAC post-CCT exhibited comparable diagnostic performance (AUC 0.818, 95 % CI: 0.79-0.85 vs. AUC 0.848, 95 % CI: 0.82-0.88; p=0.1388). Using cut-off of 56 ng/L and 59 ng/L for post-SIT and post-CCT yielded a specificity of 85 % (95 % CI: 81-88 %). Notably, to achieve a higher specificity of 90 %, the corresponding PAC cut-off values increased to 64 ng/L post-SIT and 66 ng/L post-CCT. CONCLUSIONS: Adjustment of current cut-off values for the screening and confirmation of PA is necessary when a more accurate chemiluminescent sandwich immunoassay is used for measuring PAC and PRC.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2026-06-25
DOI
https://doi.org/10.1515/cclm-2026-0579
Primary Topic
Hormonal Regulation and Hypertension
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New insights in primary aldosteronism diagnosis: a prospective multicenter study

Yajing Zhao, 郝素芳, Zhenlu Zhang, Weiyan Zhou et al.
Clinical Chemistry and Laboratory Medicine (CCLM)
Hormonal Regulation and Hypertension
article

New insights in primary aldosteronism diagnosis: a prospective multicenter study

Yajing Zhao, 郝素芳, Zhenlu Zhang, Weiyan Zhou, Hongying Cong, Zhou Zhou, Rong Chen, Wenli Cheng, Houqing Zhou, Kaijuan Wang, Hui Yuan, Ya Lin, W J, S M Yang, Wei Zhang, Wei Wu, Zhangwei Gao, Qiuping Zhao, Qifu Li, Xiaojing Gao, Poshi Xu, Jun Cai
article en

Abstract

OBJECTIVES: The high variability in screening and confirmatory cut-off values for primary aldosteronism (PA) largely reflects the insufficient standardization of current analytical methods. Competitive and sandwich immunoassays show variable correlation with the reference liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique. This prospective multicenter study aimed to establish diagnostic thresholds for PA using a novel sandwich immunoassay. METHODS: A total of 676 patients suspected of PA were consecutively enrolled from 7 medical centers in China. All participants underwent a captopril challenge test (CCT), followed by a seated saline infusion test (sSIT) on the third day. Plasma aldosterone concentration (PAC) and plasma renin concentration (PRC) were measured using a fully automated chemiluminescent immunoassay platform (Maglumi X8, SNIBE, China). PA was diagnosed according to current clinical guidelines. RESULTS: An aldosterone renin ratio (ARR) cut-off of 11 ng/L/mU/L showed 90 % sensitivity (95 % CI: 85-94 %) and 62 % specificity (95 % CI: 58-67 %) with the area under the receiver-operator characteristic curves (AUC) of 0.843 (95 % CI: 0.81-0.87). PAC post-sSIT and PAC post-CCT exhibited comparable diagnostic performance (AUC 0.818, 95 % CI: 0.79-0.85 vs. AUC 0.848, 95 % CI: 0.82-0.88; p=0.1388). Using cut-off of 56 ng/L and 59 ng/L for post-SIT and post-CCT yielded a specificity of 85 % (95 % CI: 81-88 %). Notably, to achieve a higher specificity of 90 %, the corresponding PAC cut-off values increased to 64 ng/L post-SIT and 66 ng/L post-CCT. CONCLUSIONS: Adjustment of current cut-off values for the screening and confirmation of PA is necessary when a more accurate chemiluminescent sandwich immunoassay is used for measuring PAC and PRC.

Clinical Chemistry and Laboratory Medicine (CCLM)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Wuhan University (CN), Fuwai Yunnan Cardiovascular Hospital (CN), Beijing Anzhen Hospital (CN), Wuhan Asia Heart Hospital (CN), The Affiliated Yongchuan Hospital of Chongqing Medical University (CN), Zhengzhou Central Hospital (CN), National Center for Clinical Laboratories (CN), Fu Wai Hospital (CN), Chongqing Medical University (CN)
Openalex Percentile: Top 8%
Hormonal Regulation and Hypertension
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.