Preparation of Optical-Based Sensors for the Determination of Cardiac Myosin-Binding Protein C

High Resolution Image Download MS PowerPoint Slide In this study, cardiac myosin-binding protein-C (cMyBP-C) imprinted and nonimprinted poly(2-hydroxyethyl methacrylate-N-methacryloxy-(L)-tryptophan) polymeric film-based surface plasmon resonance (SPR) sensors were prepared for the detection of cMyBP-C using the microcontact imprinting method. The surface characterization of cMyBP-C imprinted (MIP) and nonimprinted (NIP) SPR sensors was investigated using contact angle measurements and atomic force microscopy. Kinetic analyses were performed in the concentration range of 0.05–300 ng/mL, and the limits of detection and quantification were calculated as 0.019 and 0.064 ng/mL, respectively. Equilibrium, adsorption, and desorption cycles were completed for 10 min in all of the kinetic analyses. The selectivity studies of MIP SPR and NIP SPR sensors were performed using the template molecule cMyBP-C with competing molecules creatine kinase-MB (CK-MB) and cardiac troponin T (cTnT). The relative selectivity coefficients of the MIP SPR sensor for cMyBP-C/cTnT and cMyBP-C/CK-MB were found to be 3.85 and 12.64 times, respectively. The applicability of the MIP SPR sensor was determined using solutions prepared in artificial plasma samples, both in the SPR system and by enzyme-linked immunosorbent assay (ELISA).

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-06-25
DOI
https://doi.org/10.1021/acsomega.6c03802
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of Optical-Based Sensors for the Determination of Cardiac Myosin-Binding Protein C

Duygu Çimen, Mert Korkmaz, Adil Denizli
ACS Omega
Analytical chemistry methods development
article

Preparation of Optical-Based Sensors for the Determination of Cardiac Myosin-Binding Protein C

Duygu Çimen, Mert Korkmaz, Adil Denizli
article en

Abstract

High Resolution Image Download MS PowerPoint Slide In this study, cardiac myosin-binding protein-C (cMyBP-C) imprinted and nonimprinted poly(2-hydroxyethyl methacrylate-N-methacryloxy-(L)-tryptophan) polymeric film-based surface plasmon resonance (SPR) sensors were prepared for the detection of cMyBP-C using the microcontact imprinting method. The surface characterization of cMyBP-C imprinted (MIP) and nonimprinted (NIP) SPR sensors was investigated using contact angle measurements and atomic force microscopy. Kinetic analyses were performed in the concentration range of 0.05–300 ng/mL, and the limits of detection and quantification were calculated as 0.019 and 0.064 ng/mL, respectively. Equilibrium, adsorption, and desorption cycles were completed for 10 min in all of the kinetic analyses. The selectivity studies of MIP SPR and NIP SPR sensors were performed using the template molecule cMyBP-C with competing molecules creatine kinase-MB (CK-MB) and cardiac troponin T (cTnT). The relative selectivity coefficients of the MIP SPR sensor for cMyBP-C/cTnT and cMyBP-C/CK-MB were found to be 3.85 and 12.64 times, respectively. The applicability of the MIP SPR sensor was determined using solutions prepared in artificial plasma samples, both in the SPR system and by enzyme-linked immunosorbent assay (ELISA).

ACS Omega
Division of Chemistry (US), Hacettepe University (TR)
Openalex Percentile: Top 10%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.