Assessment of the extremity exposure during preparation and administration of 177Lu – results of a multi-center study

INTRODUCTION: 
Despite the increased use of 177Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of 177Lu-labelled radiopharmaceuticals in a wide range of NM practices. 

Method: 
Workers in 10 NM centers throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of 177Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. 

Results and discussion: 
The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5 µSv/GBq (range 0.5 to 525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5 µSv/GBq) showed higher normalised ring doses than those using the gravity method (3.5 µSv/GBq) or a syringe pump (1.0 µSv/GBq). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1 to 136 mSv is found, with a median fingertip dose of 10 mSv per year. 

Conclusion: 
Extremity exposure during 177Lu handling remained well below dose limits. The highest normalized doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g., shielding and minimizing time at short distance) are being applied.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-06-25
DOI
https://doi.org/10.1088/1361-6498/ae826f
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of the extremity exposure during preparation and administration of 177Lu – results of a multi-center study

Nicolas Cherbuin, Robert Kollaard, H. Datz, Ann McCann et al.
Journal of Radiological Protection
Radiation Dose and Imaging
article

Assessment of the extremity exposure during preparation and administration of 177Lu – results of a multi-center study

Nicolas Cherbuin, Robert Kollaard, H. Datz, Ann McCann, Łukasz Albiniak, Sigalit Haruz-Waschitz, Alessandra Zorz, Roel Wierts, M Ferrari, Mikko Hakulinen, Tereza Kracmerova, Jérémie Dabin, Else Aalbersberg
article en

Abstract

INTRODUCTION: 
Despite the increased use of 177Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of 177Lu-labelled radiopharmaceuticals in a wide range of NM practices. 

Method: 
Workers in 10 NM centers throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of 177Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. 

Results and discussion: 
The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5 µSv/GBq (range 0.5 to 525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5 µSv/GBq) showed higher normalised ring doses than those using the gravity method (3.5 µSv/GBq) or a syringe pump (1.0 µSv/GBq). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1 to 136 mSv is found, with a median fingertip dose of 10 mSv per year. 

Conclusion: 
Extremity exposure during 177Lu handling remained well below dose limits. The highest normalized doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g., shielding and minimizing time at short distance) are being applied.

Journal of Radiological Protection
Maastricht University Medical Centre (NL), The Netherlands Cancer Institute (NL), Tartu Art College (EE), University of Łódź (PL), Kuopio University Hospital (FI), University Hospital in Motol (CZ), Pallas (Germany) (DE), Istituto Oncologico Veneto (IT), Assaf Harofeh Medical Center (IL), Belgian Nuclear Research Centre (BE), St. Vincent's University Hospital (IE), Nuclear Research Institute Rez (Czechia) (CZ), Soreq Nuclear Research Center, European Institute of Oncology (IT)
Pioneer Fund
Good health and well-being
Openalex Percentile: Top 6%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.