Vulnerability assessment of seismically isolated elevated liquid storage tanks using optimized friction pendulum isolators with elliptical surfaces

The failure of elevated liquid storage tanks during severe earthquakes can have direct or indirect impacts on public safety. The significance of their safe performance even after destructive earthquakes and the potential for their operational use underscore the necessity for appropriate seismic design. Hence, seismic isolation, specifically base isolation, has gained attention as a seismic control method to reduce damage to these infrastructures by increasing their period of vibration. One prevalent type of seismic isolator used for tanks and other structures is the friction pendulum system (FPS) isolator. However, due to its fixed period or frequency, it may be susceptible to resonance effects during long-period earthquakes. This research explores a solution by investigating the variable curvature friction pendulum isolator (VFPI) as an alternative. This isolator type exhibits behavior similar to FPS isolators under low excitations and transforms into a pure friction system for high excitations. The study proposes optimizing this VFPI by introducing a suitable optimization function to minimize the acceleration transmitted to the superstructure, thereby improving the dynamic performance of the elevated storage tank. The research utilizes a metaheuristic algorithm for optimization and evaluates the effectiveness of the proposed isolator through time history analysis using the state space procedure under various ground motion records. Results, particularly under long-period ground motions, indicate a substantial reduction in the dynamic response of an elevated liquid storage tank equipped with the optimized VFPI. This underscores the potential of the proposed solution in enhancing the seismic resilience of liquid storage tanks.

Authors

Institutions

Publication Details

Journal
Journal of Earthquake and Tsunami
Published
2026-06-25
DOI
https://doi.org/10.1142/s179343112650020x
Primary Topic
Fluid Dynamics Simulations and Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vulnerability assessment of seismically isolated elevated liquid storage tanks using optimized friction pendulum isolators with elliptical surfaces

Naser Khaji, Mojgan Mohammadi
Journal of Earthquake and Tsunami
Fluid Dynamics Simulations and Interactions
article

Vulnerability assessment of seismically isolated elevated liquid storage tanks using optimized friction pendulum isolators with elliptical surfaces

Naser Khaji, Mojgan Mohammadi
article en

Abstract

The failure of elevated liquid storage tanks during severe earthquakes can have direct or indirect impacts on public safety. The significance of their safe performance even after destructive earthquakes and the potential for their operational use underscore the necessity for appropriate seismic design. Hence, seismic isolation, specifically base isolation, has gained attention as a seismic control method to reduce damage to these infrastructures by increasing their period of vibration. One prevalent type of seismic isolator used for tanks and other structures is the friction pendulum system (FPS) isolator. However, due to its fixed period or frequency, it may be susceptible to resonance effects during long-period earthquakes. This research explores a solution by investigating the variable curvature friction pendulum isolator (VFPI) as an alternative. This isolator type exhibits behavior similar to FPS isolators under low excitations and transforms into a pure friction system for high excitations. The study proposes optimizing this VFPI by introducing a suitable optimization function to minimize the acceleration transmitted to the superstructure, thereby improving the dynamic performance of the elevated storage tank. The research utilizes a metaheuristic algorithm for optimization and evaluates the effectiveness of the proposed isolator through time history analysis using the state space procedure under various ground motion records. Results, particularly under long-period ground motions, indicate a substantial reduction in the dynamic response of an elevated liquid storage tank equipped with the optimized VFPI. This underscores the potential of the proposed solution in enhancing the seismic resilience of liquid storage tanks.

Journal of Earthquake and Tsunami
Twitter (United States) (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 7%
Fluid Dynamics Simulations and Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Vulnerability assessment of seismically isolated elevated liquid storage tanks using optimized friction pendulum isolators with elliptical surfaces — Naser Khaji, Mojgan Mohammadi · Journal of Earthquake and Tsunami (2026) | TGRS Research Map | TGRS