A Wireless Analog Interface with Near Frame-Accurate Synchronization for Optical Motion Capture

Human kinematic analysis is an increasingly important tool in biomechanics, human performance, and wearable sensing research. Many emerging sensing modalities utilize custom sensors requiring accurate temporal alignment with ground-truth biomechanical movement data. Optical motion capture systems provide high-fidelity kinematic measurements but operate as closed, self-contained systems, making time synchronization with external sensor data non-trivial, particularly in wireless and mobile contexts. This work presents a wireless analog interface system built using commercially available components that enables alignment between analog sensor data (e.g., from custom wearables and Internet-of-Things devices) and a commercial motion capture system. The proposed architecture consists of a wearable data acquisition node and a receiver node interfaced directly with an optical motion capture system, allowing synchronized recording of analog sensor signals alongside kinematic data. Notably, the system reconstructs signals into the commercial hardware interface rather than relying on triggers or sync outputs, resulting in a single data file containing kinematics and sensor readings. Benchtop testing demonstrated a mean end-to-end frame delay of ~6 ms, with 95% of the sample exhibiting delay within 15 ms. Accounting for the typical offset, this leaves a standard deviation of 4 ms, within one motion capture frame of the true timestamp (at 100 Hz). Voltage reconstruction accuracy was within 30 mV across the tested conditions, with gain compression below 2.7%. Adjacent channel crosstalk remained below −83 dB across all test conditions. The use of commercial off-the-shelf components supports replication and adaptation by other research groups and integration with different optical motion capture systems.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-06-24
DOI
https://doi.org/10.3390/electronics15132787
Primary Topic
Network Time Synchronization Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Wireless Analog Interface with Near Frame-Accurate Synchronization for Optical Motion Capture

Emerson Noble, Kenneth J. Loh, Dr. Lucas Davis, Taylor M. Pierce et al.
Electronics
Network Time Synchronization Technologies
article

A Wireless Analog Interface with Near Frame-Accurate Synchronization for Optical Motion Capture

Emerson Noble, Kenneth J. Loh, Dr. Lucas Davis, Taylor M. Pierce, Jesus Wilkins
article en

Abstract

Human kinematic analysis is an increasingly important tool in biomechanics, human performance, and wearable sensing research. Many emerging sensing modalities utilize custom sensors requiring accurate temporal alignment with ground-truth biomechanical movement data. Optical motion capture systems provide high-fidelity kinematic measurements but operate as closed, self-contained systems, making time synchronization with external sensor data non-trivial, particularly in wireless and mobile contexts. This work presents a wireless analog interface system built using commercially available components that enables alignment between analog sensor data (e.g., from custom wearables and Internet-of-Things devices) and a commercial motion capture system. The proposed architecture consists of a wearable data acquisition node and a receiver node interfaced directly with an optical motion capture system, allowing synchronized recording of analog sensor signals alongside kinematic data. Notably, the system reconstructs signals into the commercial hardware interface rather than relying on triggers or sync outputs, resulting in a single data file containing kinematics and sensor readings. Benchtop testing demonstrated a mean end-to-end frame delay of ~6 ms, with 95% of the sample exhibiting delay within 15 ms. Accounting for the typical offset, this leaves a standard deviation of 4 ms, within one motion capture frame of the true timestamp (at 100 Hz). Voltage reconstruction accuracy was within 30 mV across the tested conditions, with gain compression below 2.7%. Adjacent channel crosstalk remained below −83 dB across all test conditions. The use of commercial off-the-shelf components supports replication and adaptation by other research groups and integration with different optical motion capture systems.

ElectronicsVol. 15(13)
University of California San Diego (US)
Openalex Percentile: Top 4%
Network Time Synchronization Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.