Performance of Free-Running Cardiac and Respiratory Motion-Resolved Whole-Heart 5D MRI in Congenital Heart Disease Patients Using a Gadolinium Enhanced Fast-Interrupted Steady-State Sequence.

Background The performance of 5D imaging in CHD has been previously demonstrated using ferumoxytol rather than gadolinium.Purpose To evaluate the performance of gadolinium enhanced 5D MRI relative to 2D and 3D MRI in CHD patients.Study Type Retrospective.Subjects 45 consecutive CHD patients referred for clinically indicated MRI who underwent 2D, 3D, and 5D MRI.Field Strength/sequence 2D bSSFP CINE, 3D bSSFP, and 5D FISS at 1.5 T.Assessment Scan time (2D, 3D, and 5D), left and right ventricular (LV, RV) end diastolic and end systolic volumes (LVEDV, RVEDV, LVESV, and RVESV, respectively), ejection fraction (LVEF, RVEF) for 2D versus 5D, and image quality on a 4-point Likert scale (3D vs. 5D).Statistical Tests Paired comparisons were made using a paired t-test or Wilcoxon signed rank test. Agreement between measurements was evaluated with Bland-Altman analysis including the bias and 95% limits of agreement.Results Scan time for 5D (6:18 [0]) was significantly shorter than 2D (7:16 [4:39]) and 3D (6:55 [1:30]) MRI. 5D measurements were strongly correlated with 2D measurements of LVEDV (R2 = 0.94), LVESV (R2 = 0.83), LVEF (R2 = 0.51), (R2 = 0.85), RVESV (R2 = 0.80), and RVEF (R2 = 0.66) but with significant biases. Sharpness of the coronary arteries were significantly higher for 3D (RCA: 36.8% ± 10.2%, LAD: 40.5% ± 10.5%) than 5D (RCA: 24.3% ± 7.5%, LAD: 31.7% ± 8.7%), but longer vessel segments were visible using 5D (LAD: 6.9 ± 2.5) than 3D (LAD: 5.3 ± 2.9 mm) acquisitions. The grades for 5D (R1: 3 [1], R2: 2.5 [0.5], R3: 3 [0.6]) were significantly higher than 3D (R1: 3 [1], R2: 2.5 [1], R3: 2 [1]).Data Conclusion Gadolinium-enhanced 5D MRI may provide an efficient and simplified acquisition for CHD patients, with multiple quantitative parameters from 5D being not significantly different from those from reference standard 2D and 3D MRI.Evidence Level 4 STAGE OF TECHNICAL EFFICACY: 1.A highly efficient and simplified method for dynamic imaging of the whole heart called five‐dimensional (5D) FISS is presented. This approach uses standard gadolinium contrast rather than previously demonstrated imaging that used off‐label ferumoxytol providing a method that can be more widely disseminated. Comparisons between 5D FISS with reference standard two and three‐dimensional imaging were performed in 45 patients with congenital heart disease. 5D FISS was not significantly different from reference standards across a number of relevant clinical parameters. These findings suggest this approach could simplify and improve cardiac imaging for patients with congenital heart disease.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-06-24
DOI
https://doi.org/10.48620/98879
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of Free-Running Cardiac and Respiratory Motion-Resolved Whole-Heart 5D MRI in Congenital Heart Disease Patients Using a Gadolinium Enhanced Fast-Interrupted Steady-State Sequence.

Matthias Stuber, Jessica Bastiaansen, Juerg Schwitter, Tobias Rutz et al.
Open Access CRIS of the University of Bern
Advanced MRI Techniques and Applications
article

Performance of Free-Running Cardiac and Respiratory Motion-Resolved Whole-Heart 5D MRI in Congenital Heart Disease Patients Using a Gadolinium Enhanced Fast-Interrupted Steady-State Sequence.

Matthias Stuber, Jessica Bastiaansen, Juerg Schwitter, Tobias Rutz, Christopher Roy, Marco Mueller, Milan Prša, Fabienne Dirbach, Jean‐Baptiste Ledoux, Alissia Megalo, Eva Vogeli, Jérôme Yerly, Estelle Tenisch, David Rodrigues
article en

Abstract

Background The performance of 5D imaging in CHD has been previously demonstrated using ferumoxytol rather than gadolinium.Purpose To evaluate the performance of gadolinium enhanced 5D MRI relative to 2D and 3D MRI in CHD patients.Study Type Retrospective.Subjects 45 consecutive CHD patients referred for clinically indicated MRI who underwent 2D, 3D, and 5D MRI.Field Strength/sequence 2D bSSFP CINE, 3D bSSFP, and 5D FISS at 1.5 T.Assessment Scan time (2D, 3D, and 5D), left and right ventricular (LV, RV) end diastolic and end systolic volumes (LVEDV, RVEDV, LVESV, and RVESV, respectively), ejection fraction (LVEF, RVEF) for 2D versus 5D, and image quality on a 4-point Likert scale (3D vs. 5D).Statistical Tests Paired comparisons were made using a paired t-test or Wilcoxon signed rank test. Agreement between measurements was evaluated with Bland-Altman analysis including the bias and 95% limits of agreement.Results Scan time for 5D (6:18 [0]) was significantly shorter than 2D (7:16 [4:39]) and 3D (6:55 [1:30]) MRI. 5D measurements were strongly correlated with 2D measurements of LVEDV (R2 = 0.94), LVESV (R2 = 0.83), LVEF (R2 = 0.51), (R2 = 0.85), RVESV (R2 = 0.80), and RVEF (R2 = 0.66) but with significant biases. Sharpness of the coronary arteries were significantly higher for 3D (RCA: 36.8% ± 10.2%, LAD: 40.5% ± 10.5%) than 5D (RCA: 24.3% ± 7.5%, LAD: 31.7% ± 8.7%), but longer vessel segments were visible using 5D (LAD: 6.9 ± 2.5) than 3D (LAD: 5.3 ± 2.9 mm) acquisitions. The grades for 5D (R1: 3 [1], R2: 2.5 [0.5], R3: 3 [0.6]) were significantly higher than 3D (R1: 3 [1], R2: 2.5 [1], R3: 2 [1]).Data Conclusion Gadolinium-enhanced 5D MRI may provide an efficient and simplified acquisition for CHD patients, with multiple quantitative parameters from 5D being not significantly different from those from reference standard 2D and 3D MRI.Evidence Level 4 STAGE OF TECHNICAL EFFICACY: 1.A highly efficient and simplified method for dynamic imaging of the whole heart called five‐dimensional (5D) FISS is presented. This approach uses standard gadolinium contrast rather than previously demonstrated imaging that used off‐label ferumoxytol providing a method that can be more widely disseminated. Comparisons between 5D FISS with reference standard two and three‐dimensional imaging were performed in 45 patients with congenital heart disease. 5D FISS was not significantly different from reference standards across a number of relevant clinical parameters. These findings suggest this approach could simplify and improve cardiac imaging for patients with congenital heart disease.

Open Access CRIS of the University of Bern
Society of Interventional Radiology (US)
Good health and well-being
Openalex Percentile: Top 6%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.