Trueness of implant placement, safety and surgeon experience with dynamic computer-assisted implant surgery : a prospective multi-centre cohort study

PURPOSE: This prospective multi-centre cohort study aims to evaluate the trueness and safety of implant placement using a Dynamic Navigation System (DNS) for implant bed preparation. MATERIALS AND METHODS: A total of 109 dental implants were inserted using a DNS for implant bed preparation in 76 patients by five experienced surgeons in four study centres. Before implantation, a preoperative CBCT scan was performed for each patient. This was subsequently aligned with an intraoral scan. After digital planning of the implant position, a holding tray for the intra-oral marker was designed and printed with a 3D printer. Procedure duration as well as adverse events were recorded. After implant bed preparation with DNS, the implants were placed in a freehand manner. Postoperative surface scans were superimposed onto the pre-operative planning data to evaluate the angular and spatial deviations. Descriptive statistics were followed by a one-sided, one-sample t-test to compare the data with performance goals extracted from literature-based benchmark data from freehand surgery. RESULTS: The overall mean angular deviation was 3.37°±2.01° with a minimum of 0.20° and a maximum of 11.10°. The mean mesiodistal and orovestibular deviation at implant tip was 1.18 ± 0.66 mm. 3D deviation at implant base showed a mean ± SD of 1.24 ± 0.65 mm. No Serious Adverse Device Effects (SADE) were reported. The angular and mesiodistal, and orovestibular deviations were significantly better than the performance goals from freehand surgery (P<.001). The mean VAS was of 87.5 ± 14.3. CONCLUSIONS: The study-related DNS demonstrates trueness, safety and surgeon satisfaction.

Authors

Institutions

Publication Details

Journal
International Journal of Implant Dentistry
Published
2026-06-25
DOI
https://doi.org/10.1186/s40729-026-00698-y
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trueness of implant placement, safety and surgeon experience with dynamic computer-assisted implant surgery : a prospective multi-centre cohort study

Sebastian Kühl, Florian Stelzle, Valentin Herber, Michael Gahlert et al.
International Journal of Implant Dentistry
Dental Implant Techniques and Outcomes
article

Trueness of implant placement, safety and surgeon experience with dynamic computer-assisted implant surgery : a prospective multi-centre cohort study

Sebastian Kühl, Florian Stelzle, Valentin Herber, Michael Gahlert, Achim von Bomhard, Marcel Hanisch, Stefan Roehling
article en

Abstract

PURPOSE: This prospective multi-centre cohort study aims to evaluate the trueness and safety of implant placement using a Dynamic Navigation System (DNS) for implant bed preparation. MATERIALS AND METHODS: A total of 109 dental implants were inserted using a DNS for implant bed preparation in 76 patients by five experienced surgeons in four study centres. Before implantation, a preoperative CBCT scan was performed for each patient. This was subsequently aligned with an intraoral scan. After digital planning of the implant position, a holding tray for the intra-oral marker was designed and printed with a 3D printer. Procedure duration as well as adverse events were recorded. After implant bed preparation with DNS, the implants were placed in a freehand manner. Postoperative surface scans were superimposed onto the pre-operative planning data to evaluate the angular and spatial deviations. Descriptive statistics were followed by a one-sided, one-sample t-test to compare the data with performance goals extracted from literature-based benchmark data from freehand surgery. RESULTS: The overall mean angular deviation was 3.37°±2.01° with a minimum of 0.20° and a maximum of 11.10°. The mean mesiodistal and orovestibular deviation at implant tip was 1.18 ± 0.66 mm. 3D deviation at implant base showed a mean ± SD of 1.24 ± 0.65 mm. No Serious Adverse Device Effects (SADE) were reported. The angular and mesiodistal, and orovestibular deviations were significantly better than the performance goals from freehand surgery (P<.001). The mean VAS was of 87.5 ± 14.3. CONCLUSIONS: The study-related DNS demonstrates trueness, safety and surgeon satisfaction.

International Journal of Implant Dentistry
University of Hohenheim (DE), University of Basel (CH), University Hospital of Basel (CH), Hospital Base (CL), University Clinic of Traumatology (AT), University Hospital Münster (DE), RoMed Kliniken (DE)
Universität Basel
Openalex Percentile: Top 6%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.