Deep Learning Based on Swin-Transformer and 3D U-Net: Implant Three-Dimensional Position Planning

INTRODUCTION AND AIMS: This study aimed to devise a deep learning-based model for the automated identification of anatomical mandibular lingual concavities in the posterior mandible and the prediction of biologically guided three-dimensional implant positions. METHODS: Cone-beam computed tomography (CBCT) images with single-tooth posterior mandibular edentulism were included. A deep learning framework was constructed utilizing 3D U-Net and Swin-Transformer. This framework was designed to perform automated segmentation of teeth, mandible, and the mandibular nerve canal; to classify morphological types of lingual concavities; and to identify implant key points with coordinate prediction. Model performance was assessed via five-fold cross-validation. RESULTS: The proposed model achieved Dice similarity coefficients ranging from 0.87 to 0.91 for dental segmentation. In the classification of mandibular lingual concavities, an accuracy of 0.92 to 0.97 was attained. Regarding the prediction of three-dimensional implant positions, the automatically generated plans maintained a safety margin of 3.20 to 3.89 mm from the mandibular nerve canal. Furthermore, sufficient bone volume was preserved at both cervical and apical implant levels, with buccal/lingual cervical bone widths averaging 4.94 to 5.78 mm. CONCLUSION: The deep learning model in this experiment performed well across different views and learning tasks in a retrospective internal validation setting. Furthermore, it demonstrated the ability to accurately identify relevant anatomical structures, and the predicted three-dimensional implant positions showed clinically acceptable safety margins in the internal validation cohort. CLINICAL RELEVANCE: This model provides a preliminary AI-assisted framework for identifying critical mandibular anatomical structures and generating biologically guided preliminary implant position suggestions, thereby helping to mitigate intraoperative complications and reduce the risk of postoperative mechanical and biological complications in preclinical evaluation.

Authors

Institutions

Publication Details

Journal
International Dental Journal
Published
2026-06-25
DOI
https://doi.org/10.1016/j.identj.2026.109690
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning Based on Swin-Transformer and 3D U-Net: Implant Three-Dimensional Position Planning

Junbiao Zhang, Minxian Ma, Yin Liu, Jiajin Shen et al.
International Dental Journal
Dental Implant Techniques and Outcomes
article

Deep Learning Based on Swin-Transformer and 3D U-Net: Implant Three-Dimensional Position Planning

Junbiao Zhang, Minxian Ma, Yin Liu, Jiajin Shen, X J Yang, Xiaohuan Lu, Guangneng Chen, Bin Ye
article en

Abstract

INTRODUCTION AND AIMS: This study aimed to devise a deep learning-based model for the automated identification of anatomical mandibular lingual concavities in the posterior mandible and the prediction of biologically guided three-dimensional implant positions. METHODS: Cone-beam computed tomography (CBCT) images with single-tooth posterior mandibular edentulism were included. A deep learning framework was constructed utilizing 3D U-Net and Swin-Transformer. This framework was designed to perform automated segmentation of teeth, mandible, and the mandibular nerve canal; to classify morphological types of lingual concavities; and to identify implant key points with coordinate prediction. Model performance was assessed via five-fold cross-validation. RESULTS: The proposed model achieved Dice similarity coefficients ranging from 0.87 to 0.91 for dental segmentation. In the classification of mandibular lingual concavities, an accuracy of 0.92 to 0.97 was attained. Regarding the prediction of three-dimensional implant positions, the automatically generated plans maintained a safety margin of 3.20 to 3.89 mm from the mandibular nerve canal. Furthermore, sufficient bone volume was preserved at both cervical and apical implant levels, with buccal/lingual cervical bone widths averaging 4.94 to 5.78 mm. CONCLUSION: The deep learning model in this experiment performed well across different views and learning tasks in a retrospective internal validation setting. Furthermore, it demonstrated the ability to accurately identify relevant anatomical structures, and the predicted three-dimensional implant positions showed clinically acceptable safety margins in the internal validation cohort. CLINICAL RELEVANCE: This model provides a preliminary AI-assisted framework for identifying critical mandibular anatomical structures and generating biologically guided preliminary implant position suggestions, thereby helping to mitigate intraoperative complications and reduce the risk of postoperative mechanical and biological complications in preclinical evaluation.

International Dental JournalVol. 76(4)
Guizhou University (CN), Zunyi Medical University (CN), Guizhou Cancer Hospital (CN), Affiliated Hospital of Guizhou Medical University (CN)
Guizhou Science and Technology Department
Openalex Percentile: Top 7%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.