Optimal Capacity Allocation of Pumped Hydro Storage Towards Long-Term High-Penetration Renewable Energy Integration: A Case Study of a Coastal Power Grid

The integration of high-penetration renewable energy creates new requirements for cross-timescale peak shaving and for system robustness under extreme meteorological conditions. This study develops a dual-timescale capacity allocation method for pumped hydro storage (PHS), combining 8760 h chronological production simulation with monthly typical-day retrospective analysis. The model represents the operating limits of conventional units, nuclear power, hydropower, wind power, photovoltaic generation, tie-line exchange, and PHS energy shifting. On this basis, a stepwise capacity-sensitivity framework is established to minimize annualized comprehensive system cost while controlling renewable energy curtailment within a predefined planning threshold, rather than treating zero curtailment as an unconditional monthly hard constraint. Using long-term planning data from a coastal provincial power grid in southeastern China, the study compares the 2035 and 2040 planning scenarios. The results show that isolated typical-day models tend to overestimate PHS requirements because they disconnect chronological continuity and cross-day reservoir buffering. In 2035, the system presents a two-level seasonal capacity structure: 15,000 MW can support normalized operation in stable months, whereas the rigid boundary rises to 19,000 MW under extreme autumn high-wind conditions. In 2040, wind and photovoltaic capacity increase by approximately 20.01 GW compared with 2035, deepening low-net-load valleys and compressing seasonal regulation margins. Under the assumed planning boundary, the recommended PHS capacity converges to 23,000 MW. The proposed framework provides a practical reference for flexible resource planning in coastal power grids with deep renewable energy integration.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-06-25
DOI
https://doi.org/10.3390/en19132982
Primary Topic
Electric Power System Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Capacity Allocation of Pumped Hydro Storage Towards Long-Term High-Penetration Renewable Energy Integration: A Case Study of a Coastal Power Grid

Han Qin, Jiquan Chen, Jinxia Yu, Guobin Ye
Energies
Electric Power System Optimization
article

Optimal Capacity Allocation of Pumped Hydro Storage Towards Long-Term High-Penetration Renewable Energy Integration: A Case Study of a Coastal Power Grid

Han Qin, Jiquan Chen, Jinxia Yu, Guobin Ye
article en

Abstract

The integration of high-penetration renewable energy creates new requirements for cross-timescale peak shaving and for system robustness under extreme meteorological conditions. This study develops a dual-timescale capacity allocation method for pumped hydro storage (PHS), combining 8760 h chronological production simulation with monthly typical-day retrospective analysis. The model represents the operating limits of conventional units, nuclear power, hydropower, wind power, photovoltaic generation, tie-line exchange, and PHS energy shifting. On this basis, a stepwise capacity-sensitivity framework is established to minimize annualized comprehensive system cost while controlling renewable energy curtailment within a predefined planning threshold, rather than treating zero curtailment as an unconditional monthly hard constraint. Using long-term planning data from a coastal provincial power grid in southeastern China, the study compares the 2035 and 2040 planning scenarios. The results show that isolated typical-day models tend to overestimate PHS requirements because they disconnect chronological continuity and cross-day reservoir buffering. In 2035, the system presents a two-level seasonal capacity structure: 15,000 MW can support normalized operation in stable months, whereas the rigid boundary rises to 19,000 MW under extreme autumn high-wind conditions. In 2040, wind and photovoltaic capacity increase by approximately 20.01 GW compared with 2035, deepening low-net-load valleys and compressing seasonal regulation margins. Under the assumed planning boundary, the recommended PHS capacity converges to 23,000 MW. The proposed framework provides a practical reference for flexible resource planning in coastal power grids with deep renewable energy integration.

EnergiesVol. 19(13)
Shanghai University of Electric Power (CN), Guizhou Water Conservancy and Hydropower Survey and Design Institute (CN)
Openalex Percentile: Top 11%
Electric Power System Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.