Intraoperative C-arm CBCT versus early postoperative MRI for the assessment of fracture reduction and osteosynthesis material positioning in cranio-maxillofacial trauma surgery

PURPOSE: To compare intraoperative C-arm cone-beam computed tomography (CBCT) with dedicated in-house-optimized magnetic resonance imaging (MRI) protocols, including CT-like and metal artifact reduction sequences (MARS), using a novel 15-channel coil for the evaluation of fracture reduction, osteosynthesis material positioning, and the depiction of plates and screws. METHODS: Fifteen patients (13 men, 2 women; median age, 32 years; range, 18-65 years) with acute cranio-maxillofacial fractures underwent surgical treatment with intraoperative CBCT, followed by early postoperative MRI within 36 h. MRI protocols included 3D ultrashort echo time (UTE), slice-encoding for metal artifact correction (SEMAC), and 3D double-echo steady-state (DESS). Two independent maxillofacial surgeons performed qualitative and quantitative evaluations of fracture reduction, osteosynthesis material positioning, and implant morphology using a 5-point visual scale (5 = best; 1 = non-assessable) and dimensional measurements. Descriptive statistics were calculated, and inter-reader agreement was assessed using weighted kappa (κ) and intraclass correlation coefficients (ICC). RESULTS: UTE and SEMAC sequences provided excellent CT-like performance in visualizing fracture reduction and implant positioning (median 5, IQR 5-5 and 4-5, respectively), with minimal absolute differences in quantitative measurements and substantial to almost perfect inter-reader agreement (κ = 0.75-1.0; ICC = 0.89-0.99; all p < 0.001). In contrast, DESS demonstrated limited utility for assessing metallic implants due to pronounced signal voids and susceptibility artifacts. CONCLUSION: UTE and SEMAC provide high-quality, radiation-free imaging for evaluating fracture reduction and osteosynthesis material in cranio-maxillofacial trauma. These techniques demonstrate comparable diagnostic performance to intraoperative CBCT in a postoperative setting. They may serve as a radiation-free alternative for perioperative imaging in younger patients with anticipated repeated imaging needs, pending prospective intraoperative validation. TRIAL REGISTRATION NUMBER: Swiss National Clinical Trials Portal: SNCTP000006343, ClinicalTrials.gov ID: NCT07012850, Registration date: May 2025.

Authors

Institutions

Publication Details

Journal
Oral and Maxillofacial Surgery
Published
2026-06-26
DOI
https://doi.org/10.1007/s10006-026-01588-8
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraoperative C-arm CBCT versus early postoperative MRI for the assessment of fracture reduction and osteosynthesis material positioning in cranio-maxillofacial trauma surgery

Sameena Sandhu, Egon Burian, Thomas Frauenfelder, Adib Al‐Haj Husain et al.
Oral and Maxillofacial Surgery
Facial Trauma and Fracture Management
article

Intraoperative C-arm CBCT versus early postoperative MRI for the assessment of fracture reduction and osteosynthesis material positioning in cranio-maxillofacial trauma surgery

Sameena Sandhu, Egon Burian, Thomas Frauenfelder, Adib Al‐Haj Husain, Stefan Sommer, Harald Essig, Maximilian E.H. Wagner, Marc M. Precht
article en

Abstract

PURPOSE: To compare intraoperative C-arm cone-beam computed tomography (CBCT) with dedicated in-house-optimized magnetic resonance imaging (MRI) protocols, including CT-like and metal artifact reduction sequences (MARS), using a novel 15-channel coil for the evaluation of fracture reduction, osteosynthesis material positioning, and the depiction of plates and screws. METHODS: Fifteen patients (13 men, 2 women; median age, 32 years; range, 18-65 years) with acute cranio-maxillofacial fractures underwent surgical treatment with intraoperative CBCT, followed by early postoperative MRI within 36 h. MRI protocols included 3D ultrashort echo time (UTE), slice-encoding for metal artifact correction (SEMAC), and 3D double-echo steady-state (DESS). Two independent maxillofacial surgeons performed qualitative and quantitative evaluations of fracture reduction, osteosynthesis material positioning, and implant morphology using a 5-point visual scale (5 = best; 1 = non-assessable) and dimensional measurements. Descriptive statistics were calculated, and inter-reader agreement was assessed using weighted kappa (κ) and intraclass correlation coefficients (ICC). RESULTS: UTE and SEMAC sequences provided excellent CT-like performance in visualizing fracture reduction and implant positioning (median 5, IQR 5-5 and 4-5, respectively), with minimal absolute differences in quantitative measurements and substantial to almost perfect inter-reader agreement (κ = 0.75-1.0; ICC = 0.89-0.99; all p < 0.001). In contrast, DESS demonstrated limited utility for assessing metallic implants due to pronounced signal voids and susceptibility artifacts. CONCLUSION: UTE and SEMAC provide high-quality, radiation-free imaging for evaluating fracture reduction and osteosynthesis material in cranio-maxillofacial trauma. These techniques demonstrate comparable diagnostic performance to intraoperative CBCT in a postoperative setting. They may serve as a radiation-free alternative for perioperative imaging in younger patients with anticipated repeated imaging needs, pending prospective intraoperative validation. TRIAL REGISTRATION NUMBER: Swiss National Clinical Trials Portal: SNCTP000006343, ClinicalTrials.gov ID: NCT07012850, Registration date: May 2025.

Oral and Maxillofacial SurgeryVol. 30(1)
University of Zurich (CH), Maastricht University Medical Centre (NL), University Hospital of Zurich (CH), Universitätsklinik Balgrist (CH), Siemens Healthcare (United States) (US)
Quality Education
Openalex Percentile: Top 6%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.