Slot, Tip, and Torque Deviations in Commercial MBT Metal Brackets

AIM: To quantify deviations in slot size, tip and torque values of commercially available MBT-prescription metal brackets relative to MBT standard. METHODS: A literature review was performed. Electronic searches were conducted between march and may 2023 via PubMed, ResearchGate and Google Scholar. A total of 16,223 records were retrieved; 58 articles were assessed by full-text screening and 20 studies were included according to predefined inclusion and exclusion criteria. RESULTS: The ideal tip value is 4 degrees; observed tip values ranged from 1.67 to 6 degrees. The ideal torque value is 17 degrees; observed torque values ranged from 7.67 to 17.81 degrees. Measured slot heights ranged from a minimum of 0.0209 inch at the base to a maximum of 0.0261 inch at the face, whereas the bracket claimed a 0.022 inch slot heights ranged from. CONCLUSION: A substantial proportion of measured brackets exhibit dimensional deviations from stated values. International standards for acceptable manufacturing tolerances and mandatory pre-market quality assessment are recommended. A consistent, repeatable measurement protocol should be established to reduce placement-related measurement error and to improve comparability across studies.

Authors

Institutions

Publication Details

Journal
Universitäts- und Landesbibliothek Münster
Published
2026-06-24
DOI
https://doi.org/10.17879/aods-2026-9800
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Slot, Tip, and Torque Deviations in Commercial MBT Metal Brackets

Aaisha Aejaz
Universitäts- und Landesbibliothek Münster
Dental materials and restorations
article

Slot, Tip, and Torque Deviations in Commercial MBT Metal Brackets

Aaisha Aejaz
article en

Abstract

AIM: To quantify deviations in slot size, tip and torque values of commercially available MBT-prescription metal brackets relative to MBT standard. METHODS: A literature review was performed. Electronic searches were conducted between march and may 2023 via PubMed, ResearchGate and Google Scholar. A total of 16,223 records were retrieved; 58 articles were assessed by full-text screening and 20 studies were included according to predefined inclusion and exclusion criteria. RESULTS: The ideal tip value is 4 degrees; observed tip values ranged from 1.67 to 6 degrees. The ideal torque value is 17 degrees; observed torque values ranged from 7.67 to 17.81 degrees. Measured slot heights ranged from a minimum of 0.0209 inch at the base to a maximum of 0.0261 inch at the face, whereas the bracket claimed a 0.022 inch slot heights ranged from. CONCLUSION: A substantial proportion of measured brackets exhibit dimensional deviations from stated values. International standards for acceptable manufacturing tolerances and mandatory pre-market quality assessment are recommended. A consistent, repeatable measurement protocol should be established to reduce placement-related measurement error and to improve comparability across studies.

Universitäts- und Landesbibliothek Münster
Bangalore Medical Center (IN), Bangalore Diabetes Centre (IN)
Reduced inequalities
Openalex Percentile: Top 6%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.