Dynamic electrocardiogram detection and diagnosis based on improved dilated convolutional network

Electrocardiograms (ECGs) are crucial for promptly detecting heart disease, assessing cardiac function, and guiding treatment, making them a key clinical tool. However, traditional ECG monitoring systems are confronted with numerous challenges. This paper presents a dynamic ECG monitoring and diagnostic system that integrates the two major developmental directions of ECG monitoring systems, namely portability and intelligent diagnosis. The portable acquisition terminal is compact, measuring only 80 mm × 100 mm and weighing approximately 150 g, so patients can easily carry it. The terminal connects to the host computer via Wi-Fi, and the acquired data is wirelessly transmitted for subsequent processing. For arrhythmia classification, this paper proposes a network architecture model that combines hybrid dilated convolution with hybrid attention mechanisms. Our hybrid dilated convolution module reduces the number of network parameters, solving key problems with traditional dilated convolution. The hybrid attention module precisely captures global dependencies in spatial and channel dimensions, enhancing diagnostic accuracy. In practical testing, the system demonstrates excellent performance. The AD8232 chip, in conjunction with Hierarchical Kalman filtering, efficiently processes ECG signals and successfully suppresses noise interference. The system maintains high accuracy, with resting heart rate measurements staying within ±2% of the true value, and exercise heart rate within ±4%. The display interface of the host computer presents clear ECG waveforms and accurate classification results. The model achieves a per-beat overall classification accuracy of 99.28% under the AAMI EC57 five-class standard, with a macro-averaged F1-score of 96.45% and a macro-averaged MCC of 0.9561 across the four evaluable classes (N, S, V, F), indicating high stability and statistical reliability.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-25
DOI
https://doi.org/10.1038/s41598-026-59403-z
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic electrocardiogram detection and diagnosis based on improved dilated convolutional network

Yinghao Jia, Zhijie Shen, Chunxiang Zhu, Hangli Wang
Scientific Reports
ECG Monitoring and Analysis
article

Dynamic electrocardiogram detection and diagnosis based on improved dilated convolutional network

Yinghao Jia, Zhijie Shen, Chunxiang Zhu, Hangli Wang
article en

Abstract

Electrocardiograms (ECGs) are crucial for promptly detecting heart disease, assessing cardiac function, and guiding treatment, making them a key clinical tool. However, traditional ECG monitoring systems are confronted with numerous challenges. This paper presents a dynamic ECG monitoring and diagnostic system that integrates the two major developmental directions of ECG monitoring systems, namely portability and intelligent diagnosis. The portable acquisition terminal is compact, measuring only 80 mm × 100 mm and weighing approximately 150 g, so patients can easily carry it. The terminal connects to the host computer via Wi-Fi, and the acquired data is wirelessly transmitted for subsequent processing. For arrhythmia classification, this paper proposes a network architecture model that combines hybrid dilated convolution with hybrid attention mechanisms. Our hybrid dilated convolution module reduces the number of network parameters, solving key problems with traditional dilated convolution. The hybrid attention module precisely captures global dependencies in spatial and channel dimensions, enhancing diagnostic accuracy. In practical testing, the system demonstrates excellent performance. The AD8232 chip, in conjunction with Hierarchical Kalman filtering, efficiently processes ECG signals and successfully suppresses noise interference. The system maintains high accuracy, with resting heart rate measurements staying within ±2% of the true value, and exercise heart rate within ±4%. The display interface of the host computer presents clear ECG waveforms and accurate classification results. The model achieves a per-beat overall classification accuracy of 99.28% under the AAMI EC57 five-class standard, with a macro-averaged F1-score of 96.45% and a macro-averaged MCC of 0.9561 across the four evaluable classes (N, S, V, F), indicating high stability and statistical reliability.

Scientific Reports
Northwestern Polytechnical University (CN), Children's Hospital of Zhejiang University (CN), China Jiliang University (CN)
Good health and well-being
Openalex Percentile: Top 9%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.