The effect of Sebia’s CZE IFCC-converted results on carbohydrate-deficient transferrin (CDT) interpretation in driver’s license assessments

OBJECTIVES: using HPLC. This study evaluates the impact of implementing Sebia's conversion equation on CDT measurements by capillary zone electrophoresis (CZE) for IFCC-alignment. METHODS: 8,309 serum samples from a driver's license regranting program and 226 samples from patients tested for congenital disorders of glycosylation (negative controls) were analyzed. Deming regression compared the original Sebia method with IFCC-aligned results following conversion. The upper limit of normal (ULN) was determined using control and population-based analyses. Age- and sex-dependent 0-sialo-Tf breakpoints were also evaluated. RESULTS: Sebia's conversion equation resulted in an upward shift in CDT within the 0-4 % range, increasing the proportion of positive samples by ∼80 % compared with the original Sebia method using a 2.3 % cut-off; applying the IFCC 2.0 % threshold still yielded a ∼50 % increase. The ULN was consistently 1.6 %, biological and analytical uncertainty correction supported the 2.0 % threshold. Although age- and sex-dependent 0-sialo-Tf breakpoints were statistically significant, exclusion of 0-sialo-Tf did not affect positivity, supporting 2-sialo-Tf as standalone marker. Longitudinal iQC monitoring confirmed reproducible quantification but revealed calibration-related positive shifts attributable to the conversion equation. CONCLUSIONS: Sebia's conversion equation increases the proportion of positive CDT results irrespective of the applied cut-off. However, our study demonstrates that Sebia's converted CDT, at a 2.0 % cut-off, is a robust marker for CDT measurement and achieves more harmonized CDT reporting.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2026-06-25
DOI
https://doi.org/10.1515/cclm-2026-0346
Primary Topic
Glycosylation and Glycoproteins Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of Sebia’s CZE IFCC-converted results on carbohydrate-deficient transferrin (CDT) interpretation in driver’s license assessments

Nathan Debunne, Veerle Compernolle, Joris Delanghe, Karen De Letter
Clinical Chemistry and Laboratory Medicine (CCLM)
Glycosylation and Glycoproteins Research
article

The effect of Sebia’s CZE IFCC-converted results on carbohydrate-deficient transferrin (CDT) interpretation in driver’s license assessments

Nathan Debunne, Veerle Compernolle, Joris Delanghe, Karen De Letter
article en

Abstract

OBJECTIVES: using HPLC. This study evaluates the impact of implementing Sebia's conversion equation on CDT measurements by capillary zone electrophoresis (CZE) for IFCC-alignment. METHODS: 8,309 serum samples from a driver's license regranting program and 226 samples from patients tested for congenital disorders of glycosylation (negative controls) were analyzed. Deming regression compared the original Sebia method with IFCC-aligned results following conversion. The upper limit of normal (ULN) was determined using control and population-based analyses. Age- and sex-dependent 0-sialo-Tf breakpoints were also evaluated. RESULTS: Sebia's conversion equation resulted in an upward shift in CDT within the 0-4 % range, increasing the proportion of positive samples by ∼80 % compared with the original Sebia method using a 2.3 % cut-off; applying the IFCC 2.0 % threshold still yielded a ∼50 % increase. The ULN was consistently 1.6 %, biological and analytical uncertainty correction supported the 2.0 % threshold. Although age- and sex-dependent 0-sialo-Tf breakpoints were statistically significant, exclusion of 0-sialo-Tf did not affect positivity, supporting 2-sialo-Tf as standalone marker. Longitudinal iQC monitoring confirmed reproducible quantification but revealed calibration-related positive shifts attributable to the conversion equation. CONCLUSIONS: Sebia's conversion equation increases the proportion of positive CDT results irrespective of the applied cut-off. However, our study demonstrates that Sebia's converted CDT, at a 2.0 % cut-off, is a robust marker for CDT measurement and achieves more harmonized CDT reporting.

Clinical Chemistry and Laboratory Medicine (CCLM)
Ghent University Hospital (BE), Ghent University (BE)
Gender equality
Openalex Percentile: Top 11%
Glycosylation and Glycoproteins Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.