A New Decomposition Method for Split-Film Thermoanemometry Probes

This paper presents a novel decomposition method for split-film probes to improve pitch angle determination over a wide range of flow velocities. Conventional approaches often suffer from the velocity dependence of the directional response function, resulting in large angular errors. The proposed method introduces a new functional formulation based on effective cooling velocities and velocity-dependent reference parameters. These parameters are explicitly derived from calibration data and modeled using fourth-order polynomial regressions to suppress velocity-induced variance. Experimental verification conducted for velocities between 2.2 and 14.6 m/s demonstrates that the proposed method collapses the calibration data more effectively than previous models. The total angular estimation error does not exceed ±2° within the pitch angle range from −60° to 60°. The proposed approach is therefore suitable for reliable measurements in low-velocity regions of complex flows, such as wakes and recirculation zones.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-06-25
DOI
https://doi.org/10.3390/pr14132066
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Decomposition Method for Split-Film Thermoanemometry Probes

Václav Uruba, Pavel Antoš
Processes
Advanced Sensor Technologies Research
article

A New Decomposition Method for Split-Film Thermoanemometry Probes

Václav Uruba, Pavel Antoš
article en

Abstract

This paper presents a novel decomposition method for split-film probes to improve pitch angle determination over a wide range of flow velocities. Conventional approaches often suffer from the velocity dependence of the directional response function, resulting in large angular errors. The proposed method introduces a new functional formulation based on effective cooling velocities and velocity-dependent reference parameters. These parameters are explicitly derived from calibration data and modeled using fourth-order polynomial regressions to suppress velocity-induced variance. Experimental verification conducted for velocities between 2.2 and 14.6 m/s demonstrates that the proposed method collapses the calibration data more effectively than previous models. The total angular estimation error does not exceed ±2° within the pitch angle range from −60° to 60°. The proposed approach is therefore suitable for reliable measurements in low-velocity regions of complex flows, such as wakes and recirculation zones.

ProcessesVol. 14(13)
Czech Academy of Sciences, Institute of Thermomechanics (CZ)
Openalex Percentile: Top 12%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A New Decomposition Method for Split-Film Thermoanemometry Probes — Václav Uruba, Pavel Antoš · Processes (2026) | TGRS Research Map | TGRS