A Contactless Edge-AI Prototype for Simulated Apnea-like Respiratory Suppression and Motion Artifact Detection Using 60 GHz FMCW Radar

Sleep-related respiratory disturbances are difficult to monitor continuously outside specialized laboratories because conventional polysomnography is resource-intensive and intrusive. This study presents a contactless edge-AI engineering prototype for detecting controlled voluntary respiratory-motion suppression and motion artifacts using a 60 GHz frequency-modulated continuous-wave radar. The system integrates a 60 GHz radar front end, lightweight local preprocessing, an INT8 one-dimensional convolutional neural network deployed on the Analog Devices MAX78000 CNN accelerator (Analog Devices Thailand, Chon Buri, Thailand), and an event-driven Raspberry Pi Zero 2W gateway for alert transmission. Evaluation was performed using a controlled healthy-volunteer dataset consisting of normal breathing, voluntary breath-holding-induced respiratory suppression, and deliberate motion artifact. The final valid test set contained 270 technically valid 30 s windows balanced across the three classes. The INT8 model achieved an overall accuracy of 92.6% (95% confidence interval: 88.8–95.2%), with a macro-averaged precision, recall, and F1-score of 92.6%, 92.6%, and 92.5%, respectively. Active CNN inference on the MAX78000 consumed 0.152 ± 0.011 mJ and was completed in 5.20 ± 0.11 ms, corresponding to approximately 280-fold lower active inference energy than Python 3.14.6/TensorFlow Lite 2.21.0-based execution on the Raspberry Pi Zero 2W. These results demonstrate the feasibility of privacy-aware, low-power respiratory-pattern classification at the edge. However, the study should be interpreted strictly as an engineering proof-of-concept based on controlled voluntary breathing and movement tasks in healthy volunteers. It is not a clinically validated apnea or obstructive sleep apnea detection system and did not include polysomnography, oxygen saturation measurement, airflow sensing, sleep staging, or diagnosed patient cohorts.

Authors

Institutions

Publication Details

Journal
Technologies
Published
2026-06-24
DOI
https://doi.org/10.3390/technologies14070388
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Contactless Edge-AI Prototype for Simulated Apnea-like Respiratory Suppression and Motion Artifact Detection Using 60 GHz FMCW Radar

Pattarapong Phasukkit, Sathit Pairoch, Nongluck Houngkamhang
Technologies
Non-Invasive Vital Sign Monitoring
article

A Contactless Edge-AI Prototype for Simulated Apnea-like Respiratory Suppression and Motion Artifact Detection Using 60 GHz FMCW Radar

Pattarapong Phasukkit, Sathit Pairoch, Nongluck Houngkamhang
article en

Abstract

Sleep-related respiratory disturbances are difficult to monitor continuously outside specialized laboratories because conventional polysomnography is resource-intensive and intrusive. This study presents a contactless edge-AI engineering prototype for detecting controlled voluntary respiratory-motion suppression and motion artifacts using a 60 GHz frequency-modulated continuous-wave radar. The system integrates a 60 GHz radar front end, lightweight local preprocessing, an INT8 one-dimensional convolutional neural network deployed on the Analog Devices MAX78000 CNN accelerator (Analog Devices Thailand, Chon Buri, Thailand), and an event-driven Raspberry Pi Zero 2W gateway for alert transmission. Evaluation was performed using a controlled healthy-volunteer dataset consisting of normal breathing, voluntary breath-holding-induced respiratory suppression, and deliberate motion artifact. The final valid test set contained 270 technically valid 30 s windows balanced across the three classes. The INT8 model achieved an overall accuracy of 92.6% (95% confidence interval: 88.8–95.2%), with a macro-averaged precision, recall, and F1-score of 92.6%, 92.6%, and 92.5%, respectively. Active CNN inference on the MAX78000 consumed 0.152 ± 0.011 mJ and was completed in 5.20 ± 0.11 ms, corresponding to approximately 280-fold lower active inference energy than Python 3.14.6/TensorFlow Lite 2.21.0-based execution on the Raspberry Pi Zero 2W. These results demonstrate the feasibility of privacy-aware, low-power respiratory-pattern classification at the edge. However, the study should be interpreted strictly as an engineering proof-of-concept based on controlled voluntary breathing and movement tasks in healthy volunteers. It is not a clinically validated apnea or obstructive sleep apnea detection system and did not include polysomnography, oxygen saturation measurement, airflow sensing, sleep staging, or diagnosed patient cohorts.

TechnologiesVol. 14(7)
King Mongkut's Institute of Technology Ladkrabang (TH)
Openalex Percentile: Top 12%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.