Assessment of modifications to a blind-sweep ultrasound protocol for improved lower-uterus imaging by novice operators

Blind-sweep ultrasound protocols may improve prenatal care in low-resource settings, but lower-uterus visualization is often insufficient when performed by novices. We evaluated three modifications to a standard protocol aimed at improving lower-uterus imaging: Step A (caudal probe tilt), Step B (caudal sweep with probe angled caudally), and Step C (caudo-cranial sweep with lower probe placement). Outcomes included fetal head visibility, number of scans with measurable head circumference (HC), and agreement with clinical HC measurements. Adding Steps A or B substantially increased fetal head visibility and the proportion of scans with measurable HC. Step A produced the largest improvement, raising scans with [Formula: see text] head visibility from 25.5% to 93.8%, and increasing measurable HC from 55.2% to 99.5% for a reader experienced in blind-sweep analysis ([Formula: see text]), and from 7.8% to 74.8% in a subset ([Formula: see text]) annotated by an obstetric gynecologist. These gains were concentrated in scans where the standard protocol failed to visualize the fetal head, with no significant benefit when at least partial visibility was already achieved. Bias and limits of agreement with clinical HC were similar across all variants, indicating accurate measurements when usable frames were available. Step C provided minimal improvement. Insufficient lower-uterus visualization is a frequent but easily correctable limitation of blind-sweep protocols performed with minimal supervision. A simple caudal tilt (Step A) enhances fetal head visibility and measurable HC rate, supporting its integration into standardized protocols for novices. Prospective validation in low-resource settings is needed to confirm generalizability under varying training and supervision conditions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-25
DOI
https://doi.org/10.1038/s41598-026-59278-0
Primary Topic
Neonatal and fetal brain pathology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of modifications to a blind-sweep ultrasound protocol for improved lower-uterus imaging by novice operators

Jeroen van Dillen, M. Sofía Sappia, Bram van Ginneken, Chris L. de Korte et al.
Scientific Reports
Neonatal and fetal brain pathology
article

Assessment of modifications to a blind-sweep ultrasound protocol for improved lower-uterus imaging by novice operators

Jeroen van Dillen, M. Sofía Sappia, Bram van Ginneken, Chris L. de Korte, Keelin Murphy
article en

Abstract

Blind-sweep ultrasound protocols may improve prenatal care in low-resource settings, but lower-uterus visualization is often insufficient when performed by novices. We evaluated three modifications to a standard protocol aimed at improving lower-uterus imaging: Step A (caudal probe tilt), Step B (caudal sweep with probe angled caudally), and Step C (caudo-cranial sweep with lower probe placement). Outcomes included fetal head visibility, number of scans with measurable head circumference (HC), and agreement with clinical HC measurements. Adding Steps A or B substantially increased fetal head visibility and the proportion of scans with measurable HC. Step A produced the largest improvement, raising scans with [Formula: see text] head visibility from 25.5% to 93.8%, and increasing measurable HC from 55.2% to 99.5% for a reader experienced in blind-sweep analysis ([Formula: see text]), and from 7.8% to 74.8% in a subset ([Formula: see text]) annotated by an obstetric gynecologist. These gains were concentrated in scans where the standard protocol failed to visualize the fetal head, with no significant benefit when at least partial visibility was already achieved. Bias and limits of agreement with clinical HC were similar across all variants, indicating accurate measurements when usable frames were available. Step C provided minimal improvement. Insufficient lower-uterus visualization is a frequent but easily correctable limitation of blind-sweep protocols performed with minimal supervision. A simple caudal tilt (Step A) enhances fetal head visibility and measurable HC rate, supporting its integration into standardized protocols for novices. Prospective validation in low-resource settings is needed to confirm generalizability under varying training and supervision conditions.

Scientific Reports
Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Radboud Institute for Molecular Life Sciences (NL), University of Twente (NL)
Radboud Universitair Medisch Centrum
Openalex Percentile: Top 6%
Neonatal and fetal brain pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.