Cumulative radiation exposure from repeated CT imaging in hospitalised COVID-19 patients: Does it matter?

Purpose To assess cumulative radiation exposure associated with repeated CT imaging in hospitalized COVID-19 patients and to identify factors contributing to high cumulative dose. Materials and Methods This retrospective observational study included 69 adult patients with confirmed COVID-19 who underwent three or more CT examinations during a single hospitalization. A total of 296 CT examinations comprising 350 acquisition phases were analyzed. Dose parameters (CTDIvol, DLP) were recorded, and cumulative effective dose (CED) was calculated using region-specific conversion factors. Continuous variables were expressed as median with interquartile range (IQR). Results The median cumulative effective dose was 47.7 mSv (IQR 34.5–87.2; range 18.0–342.6). A total of 32 patients (46.4%) accumulated ≥ 50 mSv, while 16 patients (23.2%) exceeded 100 mSv during a single hospitalization, including one patient (1.4%) with exposure ≥ 200 mSv. CED showed a moderate correlation with the number of CT examinations (ρ=0.37, p = 0.0016) and a stronger correlation with the total number of acquisition phases (ρ=0.54, p < 0.00001). Patients with CED ≥ 100 mSv had a higher median number of acquisition phases (5.5 vs 3), whereas the difference in the number of CT examinations was less pronounced (4.5 vs 4). Non-contrast chest CT accounted for 70.95% of all examinations. Conclusion Repeated and multiphase CT imaging resulted in substantial cumulative radiation exposure in a selected subgroup of hospitalised COVID-19 patients. Nearly one quarter of patients exceeded 100 mSv during a single hospitalisation. These findings support careful justification of repeated CT examinations, limitation of multiphasic acquisitions when clinically feasible, and systematic dose monitoring in patients requiring intensive imaging follow-up.

Authors

Institutions

Publication Details

Journal
European Journal of Radiology Open
Published
2026-06-26
DOI
https://doi.org/10.1016/j.ejro.2026.100785
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cumulative radiation exposure from repeated CT imaging in hospitalised COVID-19 patients: Does it matter?

Desislava Z. Kostova-Lefterova, Dora Zlatareva, Marieta Mateva-Mladenova, Stefan Stanev
European Journal of Radiology Open
Radiation Dose and Imaging
article

Cumulative radiation exposure from repeated CT imaging in hospitalised COVID-19 patients: Does it matter?

Desislava Z. Kostova-Lefterova, Dora Zlatareva, Marieta Mateva-Mladenova, Stefan Stanev
article en

Abstract

Purpose To assess cumulative radiation exposure associated with repeated CT imaging in hospitalized COVID-19 patients and to identify factors contributing to high cumulative dose. Materials and Methods This retrospective observational study included 69 adult patients with confirmed COVID-19 who underwent three or more CT examinations during a single hospitalization. A total of 296 CT examinations comprising 350 acquisition phases were analyzed. Dose parameters (CTDIvol, DLP) were recorded, and cumulative effective dose (CED) was calculated using region-specific conversion factors. Continuous variables were expressed as median with interquartile range (IQR). Results The median cumulative effective dose was 47.7 mSv (IQR 34.5–87.2; range 18.0–342.6). A total of 32 patients (46.4%) accumulated ≥ 50 mSv, while 16 patients (23.2%) exceeded 100 mSv during a single hospitalization, including one patient (1.4%) with exposure ≥ 200 mSv. CED showed a moderate correlation with the number of CT examinations (ρ=0.37, p = 0.0016) and a stronger correlation with the total number of acquisition phases (ρ=0.54, p < 0.00001). Patients with CED ≥ 100 mSv had a higher median number of acquisition phases (5.5 vs 3), whereas the difference in the number of CT examinations was less pronounced (4.5 vs 4). Non-contrast chest CT accounted for 70.95% of all examinations. Conclusion Repeated and multiphase CT imaging resulted in substantial cumulative radiation exposure in a selected subgroup of hospitalised COVID-19 patients. Nearly one quarter of patients exceeded 100 mSv during a single hospitalisation. These findings support careful justification of repeated CT examinations, limitation of multiphasic acquisitions when clinically feasible, and systematic dose monitoring in patients requiring intensive imaging follow-up.

European Journal of Radiology OpenVol. 17
Alexandrovska Hospital (BG), Medical University of Sofia (BG), National Heart Hospital (BG), Agricultural University Plovdiv (BG), Medical University Pleven (BG)
Openalex Percentile: Top 7%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.