Adherence of CLAIM in Artificial Intelligence Research: A Cross‐Sectional Study

OBJECTIVE: To analyze the adherence of Checklist for Artificial Intelligence (AI) in Medical Imaging (CLAIM) in top medical imaging journals. METHODS: A search for AI research in top medical imaging journals was performed from Web of Science Core Collection. The adherence was assessed by the reporting score and compliance rate of CLAIM. Potential influencing factors were also analyzed. RESULTS: A total of 501 articles were included. After quality assessment, the median CLAIM score was 19 points (25th-75th: 17-21 points), and the median overall compliance rate was 51.4% (25th-75th: 46.2%-57.9%). Among the 42 items, 14 items had compliance rates of ≥80%, 11 items had compliance rates of 40%-79%, while 17 items had compliance rates of <40%. Low compliance rates were predominantly concentrated on items such as quality control of annotations, sample size determination, model robustness evaluation, failure analysis, and code/data availability. In terms of temporal trends, both the overall score (ρ = 0.119, p = 0.008) and compliance rate (ρ = 0.139, p = 0.002) showed weak positive correlations with the publication year. Furthermore, compliance for items 2 (structured abstract) (ρ = 0.129, p = 0.004), 33 (participant flow diagram) (ρ = 0.131, p = 0.003), 34 (demographic/clinical characteristics by partition) (ρ = 0.122, p = 0.006), 41 (study protocol/data/code availability) (ρ = 0.094, p = 0.036), and 42 (funding sources) (ρ = 0.128, p = 0.004) demonstrated significant upward trends over time. Logistic regression analysis identified the following negative predictors of reporting quality: research objectives focused on image reconstruction (OR = 0.416, 95% CI: 0.203-0.842, p = 0.015), artifact reduction (OR = 0.072, 95% CI: 0.009-0.365, p = 0.004), multimodal imaging (OR = 0.301, 95% CI: 0.090-0.899, p = 0.038), use of public (OR = 0.508, 95% CI: 0.289-0.883, p = 0.017) and public-private hybrid (OR = 0.339, 95% CI: 0.146-0.759, p = 0.010) development datasets. Conversely, positive predictors were: publication year (OR = 1.246, 95% CI: 1.067-1.458, p = 0.006); being published in a CLAIM adopting journal (OR = 1.737, 95% CI: 1.070-2.481, p = 0.026); code availability (OR = 1.929, 95% CI: 1.181-3.186, p = 0.009); and development datasets sizes of 100-199 cases (OR = 2.187, 95% CI: 1.121-4.320, p = 0.023), 500-999 cases (OR = 3.409, 95% CI: 1.508-7.902, p = 0.004), and ≥1000 cases (OR = 2.798, 95% CI: 1.335-5.979, p = 0.007). CONCLUSIONS: The adherence of CLAIM among AI research in top medical imaging journals is still inadequate. It is needed to join efforts of researchers, editors, and reviewers to strengthen the application of CLAIM to improve the research quality and reproducibility.

Authors

Institutions

Publication Details

Journal
Journal of Evidence-Based Medicine
Published
2026-06-25
DOI
https://doi.org/10.1111/jebm.70141
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adherence of CLAIM in Artificial Intelligence Research: A Cross‐Sectional Study

Na Li, Bingran Zhang, Renjie Zhao, Yonggang Zhang et al.
Journal of Evidence-Based Medicine
Artificial Intelligence in Healthcare and Education
article

Adherence of CLAIM in Artificial Intelligence Research: A Cross‐Sectional Study

Na Li, Bingran Zhang, Renjie Zhao, Yonggang Zhang, Xi Zhang, Zhongfan Liao, Ying Wang, Wenjie Yang, Yilan Zhang, Chenhao Gao
article en

Abstract

OBJECTIVE: To analyze the adherence of Checklist for Artificial Intelligence (AI) in Medical Imaging (CLAIM) in top medical imaging journals. METHODS: A search for AI research in top medical imaging journals was performed from Web of Science Core Collection. The adherence was assessed by the reporting score and compliance rate of CLAIM. Potential influencing factors were also analyzed. RESULTS: A total of 501 articles were included. After quality assessment, the median CLAIM score was 19 points (25th-75th: 17-21 points), and the median overall compliance rate was 51.4% (25th-75th: 46.2%-57.9%). Among the 42 items, 14 items had compliance rates of ≥80%, 11 items had compliance rates of 40%-79%, while 17 items had compliance rates of <40%. Low compliance rates were predominantly concentrated on items such as quality control of annotations, sample size determination, model robustness evaluation, failure analysis, and code/data availability. In terms of temporal trends, both the overall score (ρ = 0.119, p = 0.008) and compliance rate (ρ = 0.139, p = 0.002) showed weak positive correlations with the publication year. Furthermore, compliance for items 2 (structured abstract) (ρ = 0.129, p = 0.004), 33 (participant flow diagram) (ρ = 0.131, p = 0.003), 34 (demographic/clinical characteristics by partition) (ρ = 0.122, p = 0.006), 41 (study protocol/data/code availability) (ρ = 0.094, p = 0.036), and 42 (funding sources) (ρ = 0.128, p = 0.004) demonstrated significant upward trends over time. Logistic regression analysis identified the following negative predictors of reporting quality: research objectives focused on image reconstruction (OR = 0.416, 95% CI: 0.203-0.842, p = 0.015), artifact reduction (OR = 0.072, 95% CI: 0.009-0.365, p = 0.004), multimodal imaging (OR = 0.301, 95% CI: 0.090-0.899, p = 0.038), use of public (OR = 0.508, 95% CI: 0.289-0.883, p = 0.017) and public-private hybrid (OR = 0.339, 95% CI: 0.146-0.759, p = 0.010) development datasets. Conversely, positive predictors were: publication year (OR = 1.246, 95% CI: 1.067-1.458, p = 0.006); being published in a CLAIM adopting journal (OR = 1.737, 95% CI: 1.070-2.481, p = 0.026); code availability (OR = 1.929, 95% CI: 1.181-3.186, p = 0.009); and development datasets sizes of 100-199 cases (OR = 2.187, 95% CI: 1.121-4.320, p = 0.023), 500-999 cases (OR = 3.409, 95% CI: 1.508-7.902, p = 0.004), and ≥1000 cases (OR = 2.798, 95% CI: 1.335-5.979, p = 0.007). CONCLUSIONS: The adherence of CLAIM among AI research in top medical imaging journals is still inadequate. It is needed to join efforts of researchers, editors, and reviewers to strengthen the application of CLAIM to improve the research quality and reproducibility.

Journal of Evidence-Based Medicine
University of Electronic Science and Technology of China (CN), Sichuan University (CN), West China Medical Center of Sichuan University (CN), West China Hospital of Sichuan University (CN)
Openalex Percentile: Top 10%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.