An Enhanced Type 3 Phase-Locked Loop with Improved Frequency Estimation Capability Under Grid Distortion

This paper proposes an enhanced Type 3 phase-locked loop (ET3-PLL) to improve the frequency estimation performance of the conventional Type 3 synchronous reference frame PLL (SRF-PLL) under harmonic distortion. Frequency response analysis of the conventional Type 3 SRF-PLL reveals its limited ability to reject harmonic disturbances in frequency estimation. To address this limitation, the ET3-PLL is introduced. Its small-signal model is established, and comparative frequency-domain analysis shows that the ET3-PLL provides superior frequency estimation performance under harmonic distortion. Moreover, large-signal analysis of the phase error dynamics indicates that the ET3-PLL achieves exactly the same phase-tracking performance as the conventional Type 3 SRF-PLL. Experimental results under various grid conditions validate the effectiveness of the proposed method.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-06-24
DOI
https://doi.org/10.3390/eng7070306
Primary Topic
Advancements in PLL and VCO Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Enhanced Type 3 Phase-Locked Loop with Improved Frequency Estimation Capability Under Grid Distortion

Zhiyong Dai, Guangqi Li, Yihua Zhu, Xuetong Wang et al.
Eng—Advances in Engineering
Advancements in PLL and VCO Technologies
article

An Enhanced Type 3 Phase-Locked Loop with Improved Frequency Estimation Capability Under Grid Distortion

Zhiyong Dai, Guangqi Li, Yihua Zhu, Xuetong Wang, Youfeng Zhou, Chao Luo, Jiawei Yu
article en

Abstract

This paper proposes an enhanced Type 3 phase-locked loop (ET3-PLL) to improve the frequency estimation performance of the conventional Type 3 synchronous reference frame PLL (SRF-PLL) under harmonic distortion. Frequency response analysis of the conventional Type 3 SRF-PLL reveals its limited ability to reject harmonic disturbances in frequency estimation. To address this limitation, the ET3-PLL is introduced. Its small-signal model is established, and comparative frequency-domain analysis shows that the ET3-PLL provides superior frequency estimation performance under harmonic distortion. Moreover, large-signal analysis of the phase error dynamics indicates that the ET3-PLL achieves exactly the same phase-tracking performance as the conventional Type 3 SRF-PLL. Experimental results under various grid conditions validate the effectiveness of the proposed method.

Eng—Advances in EngineeringVol. 7(7)
Xidian University (CN), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
Advancements in PLL and VCO Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.