Concurrent Validity and Reliability of Inertial Sensor-Based Wearables for Quantifying Spatial–Temporal Gait Parameters After Stroke: A Systematic Review

This systematic review examined the validity and reliability of wearable inertial sensor systems to quantify spatiotemporal gait parameters in post-stroke adults, a population in which gait asymmetry and altered motor control challenge accurate measurement. Sixteen studies involving 300 participants were included. Spatial parameters gait speed, cadence, and step/stride length showed consistently good-to-excellent agreement with reference systems (ICC 0.85–0.98; 95% LoA ±0.03–0.08 m/s for gait speed, ±4–10 steps/min for cadence, and ±3–8 cm for step/stride length) and high test–retest reliability. Temporal parameters demonstrated greater heterogeneity, with larger errors and lower concordance (ICC 0.40–0.85; LoA ±0.04–0.12 s), particularly for swing time (ICC 0.40–0.70; LoA up to ±0.15 s). Paretic-side measurements showed 10–20% lower concordance and 30–50% wider limits of agreement compared with the non-paretic side, although within-subject reliability remained moderate to high. No consistent influence of sensor number on measurement accuracy was observed. Overall, wearable inertial sensors provide robust estimates of spatial gait parameters, whereas temporal outcomes especially swing time remain limited due to challenges in gait event detection under stroke-related biomechanical alterations. These findings highlight the need for standardized protocols and improved algorithms to enhance comparability across studies and support broader clinical adoption.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2026-06-24
DOI
https://doi.org/10.3390/brainsci16070662
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concurrent Validity and Reliability of Inertial Sensor-Based Wearables for Quantifying Spatial–Temporal Gait Parameters After Stroke: A Systematic Review

Ivo D. Popivanov, L. Traykov, Jonatan García Campos, C Díaz-Marín et al.
Brain Sciences
Balance, Gait, and Falls Prevention
article

Concurrent Validity and Reliability of Inertial Sensor-Based Wearables for Quantifying Spatial–Temporal Gait Parameters After Stroke: A Systematic Review

Ivo D. Popivanov, L. Traykov, Jonatan García Campos, C Díaz-Marín, David Barbado, Pablo Ros‐Arlanzón, Shima Mehrabian-Spasova, C Blasco-Peris, Elisabeth García-Alonso, Luis Moreno-Navarro, Diana Salas-Gómez, Bernardino Morillo-Merino, Víctor Martínez-Pozo
article en

Abstract

This systematic review examined the validity and reliability of wearable inertial sensor systems to quantify spatiotemporal gait parameters in post-stroke adults, a population in which gait asymmetry and altered motor control challenge accurate measurement. Sixteen studies involving 300 participants were included. Spatial parameters gait speed, cadence, and step/stride length showed consistently good-to-excellent agreement with reference systems (ICC 0.85–0.98; 95% LoA ±0.03–0.08 m/s for gait speed, ±4–10 steps/min for cadence, and ±3–8 cm for step/stride length) and high test–retest reliability. Temporal parameters demonstrated greater heterogeneity, with larger errors and lower concordance (ICC 0.40–0.85; LoA ±0.04–0.12 s), particularly for swing time (ICC 0.40–0.70; LoA up to ±0.15 s). Paretic-side measurements showed 10–20% lower concordance and 30–50% wider limits of agreement compared with the non-paretic side, although within-subject reliability remained moderate to high. No consistent influence of sensor number on measurement accuracy was observed. Overall, wearable inertial sensors provide robust estimates of spatial gait parameters, whereas temporal outcomes especially swing time remain limited due to challenges in gait event detection under stroke-related biomechanical alterations. These findings highlight the need for standardized protocols and improved algorithms to enhance comparability across studies and support broader clinical adoption.

Brain SciencesVol. 16(7)
Universitat de Miguel Hernández d'Elx (ES), New Bulgarian University (BG), Alexandrovska Hospital (BG), Medical University of Sofia (BG), Instituto de Arqueología-Mérida (ES), Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL) (ES)
Openalex Percentile: Top 4%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.