Accuracy of Contemporary Intraocular Lens Calculation Formulas Based on Swept-Source OCT Biometry in Eyes with Capsular Tension Ring

Objectives: To compare the refractive prediction accuracy of contemporary intraocular lens (IOL) calculation formulas based on swept-source optical coherence tomography (OCT) biometry in cataract surgery with capsular tension ring (CTR) implantation, and to assess for systematic postoperative refractive tendencies. Materials and Methods: This retrospective study included 98 eyes of 92 patients who underwent phacoemulsification with in-the-bag IOL and CTR implantation. Preoperative biometry utilized swept-source OCT (ARGOS, Alcon). Refractive prediction accuracy was evaluated for the Barrett Universal II, Haigis, SRK/T, and Holladay II formulas. Main outcomes included mean prediction error, mean absolute error (MAE), median absolute error (MedAE), and percentages of eyes within ±0.25, ±0.50, and ±1.00 diopter (D). Results: The mean age was 73.0±8.1 years, and the mean axial length was 23.03±1.04 mm. Barrett Universal II yielded the lowest MAE and MedAE (0.36±0.34 D and 0.24 D, respectively), followed by Holladay II (0.40±0.32 D and 0.30 D). Higher MAE was observed with SRK/T (0.45±0.37 D) and Haigis (0.54±0.45 D). MAE differed significantly among the formulas (p<0.001), with pairwise comparisons showing that Barrett Universal II and Holladay II performed similarly (p>0.05) and better than both Haigis and SRK/T (all p≤0.003). The highest percentage of eyes within ±0.25 D was observed with Barrett Universal II (52.04%), whereas Holladay II showed the highest percentage within ±0.50 D (69.39%), and the two formulas tied within the ±1.00 D range (both 92.86%). Prediction errors were positive for all formulas, indicating a mild hyperopic shift. Conclusion: In eyes undergoing cataract surgery with CTR implantation, Barrett Universal II and Holladay II showed more favorable refractive prediction accuracy than Haigis and SRK/T. A mild hyperopic shift was observed across all formulas. This finding may be clinically relevant when selecting the target refraction or IOL power in these eyes.

Authors

Institutions

Publication Details

Journal
Turkish Journal of Ophthalmology
Published
2026-06-24
DOI
https://doi.org/10.4274/tjo.galenos.2026.33338
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Contemporary Intraocular Lens Calculation Formulas Based on Swept-Source OCT Biometry in Eyes with Capsular Tension Ring

Ali Devebacak, Müge Yılmaz, Gül Arıkan
Turkish Journal of Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Accuracy of Contemporary Intraocular Lens Calculation Formulas Based on Swept-Source OCT Biometry in Eyes with Capsular Tension Ring

Ali Devebacak, Müge Yılmaz, Gül Arıkan
article en

Abstract

Objectives: To compare the refractive prediction accuracy of contemporary intraocular lens (IOL) calculation formulas based on swept-source optical coherence tomography (OCT) biometry in cataract surgery with capsular tension ring (CTR) implantation, and to assess for systematic postoperative refractive tendencies. Materials and Methods: This retrospective study included 98 eyes of 92 patients who underwent phacoemulsification with in-the-bag IOL and CTR implantation. Preoperative biometry utilized swept-source OCT (ARGOS, Alcon). Refractive prediction accuracy was evaluated for the Barrett Universal II, Haigis, SRK/T, and Holladay II formulas. Main outcomes included mean prediction error, mean absolute error (MAE), median absolute error (MedAE), and percentages of eyes within ±0.25, ±0.50, and ±1.00 diopter (D). Results: The mean age was 73.0±8.1 years, and the mean axial length was 23.03±1.04 mm. Barrett Universal II yielded the lowest MAE and MedAE (0.36±0.34 D and 0.24 D, respectively), followed by Holladay II (0.40±0.32 D and 0.30 D). Higher MAE was observed with SRK/T (0.45±0.37 D) and Haigis (0.54±0.45 D). MAE differed significantly among the formulas (p<0.001), with pairwise comparisons showing that Barrett Universal II and Holladay II performed similarly (p>0.05) and better than both Haigis and SRK/T (all p≤0.003). The highest percentage of eyes within ±0.25 D was observed with Barrett Universal II (52.04%), whereas Holladay II showed the highest percentage within ±0.50 D (69.39%), and the two formulas tied within the ±1.00 D range (both 92.86%). Prediction errors were positive for all formulas, indicating a mild hyperopic shift. Conclusion: In eyes undergoing cataract surgery with CTR implantation, Barrett Universal II and Holladay II showed more favorable refractive prediction accuracy than Haigis and SRK/T. A mild hyperopic shift was observed across all formulas. This finding may be clinically relevant when selecting the target refraction or IOL power in these eyes.

Turkish Journal of OphthalmologyVol. 56(3)
Dokuz Eylül University (TR)
Openalex Percentile: Top 7%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.