Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants

BACKGROUND: Native polyetheretherketone (PEEK) exhibits limitations in mechanical strength, radiographic visibility, and bioactivity for craniomaxillofacial (CMF) applications. This proof-of-concept study establishes the feasibility of point-of-care (POC) manufacturing for three functionalized PEEK composites for patient-specific CMF implants using a high-temperature material extrusion (MEX) system, with application-specific material selection to overcome these limitations. METHODS: Carbon fiber-reinforced PEEK (CFR-PEEK), barium sulfate-filled PEEK (BaSO₄-PEEK), and biphasic calcium phosphate-filled PEEK (BCP-PEEK) were fabricated into patient-specific mandibular reconstruction plates, orbital floor implants, and chin augmentation implants, respectively. Manufacturing success rates, dimensional accuracy via root mean square (RMS) deviation analysis, post-sterilization dimensional stability, and layer adhesion quality were evaluated. RESULTS: Fabrication success rates of 100% (CFR-PEEK), 100% (BaSO₄-PEEK), and 85.7% (BCP-PEEK) were achieved. Dimensional accuracy analysis revealed RMS deviations of 0.16-0.29 mm between 3D-printed implants and original designs, within clinically acceptable ranges. Post-sterilization dimensional changes were minimal (RMS 0.05-0.07 mm). Complete layer adhesion was demonstrated across all materials, with no delamination or cracking observed. CONCLUSION: These findings establish the manufacturing viability of POC fabrication of application-matched PEEK composites for patient-specific CMF implants, enhancing mechanical, radiographic, and bioactive properties whilst maintaining geometric customization.

Authors

Institutions

Publication Details

Journal
3D Printing in Medicine
Published
2026-06-24
DOI
https://doi.org/10.1186/s41205-026-00331-z
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants

Jokin Zubizarreta Oteiza, Daniel Seiler, Florian M. Thieringer, Yannick Krieger et al.
3D Printing in Medicine
Facial Trauma and Fracture Management
article

Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants

Jokin Zubizarreta Oteiza, Daniel Seiler, Florian M. Thieringer, Yannick Krieger, Neha Sharma
article en

Abstract

BACKGROUND: Native polyetheretherketone (PEEK) exhibits limitations in mechanical strength, radiographic visibility, and bioactivity for craniomaxillofacial (CMF) applications. This proof-of-concept study establishes the feasibility of point-of-care (POC) manufacturing for three functionalized PEEK composites for patient-specific CMF implants using a high-temperature material extrusion (MEX) system, with application-specific material selection to overcome these limitations. METHODS: Carbon fiber-reinforced PEEK (CFR-PEEK), barium sulfate-filled PEEK (BaSO₄-PEEK), and biphasic calcium phosphate-filled PEEK (BCP-PEEK) were fabricated into patient-specific mandibular reconstruction plates, orbital floor implants, and chin augmentation implants, respectively. Manufacturing success rates, dimensional accuracy via root mean square (RMS) deviation analysis, post-sterilization dimensional stability, and layer adhesion quality were evaluated. RESULTS: Fabrication success rates of 100% (CFR-PEEK), 100% (BaSO₄-PEEK), and 85.7% (BCP-PEEK) were achieved. Dimensional accuracy analysis revealed RMS deviations of 0.16-0.29 mm between 3D-printed implants and original designs, within clinically acceptable ranges. Post-sterilization dimensional changes were minimal (RMS 0.05-0.07 mm). Complete layer adhesion was demonstrated across all materials, with no delamination or cracking observed. CONCLUSION: These findings establish the manufacturing viability of POC fabrication of application-matched PEEK composites for patient-specific CMF implants, enhancing mechanical, radiographic, and bioactive properties whilst maintaining geometric customization.

3D Printing in MedicineVol. 12(1)
University Hospital of Basel (CH), FHNW University of Applied Sciences and Arts Northwestern Switzerland (CH), Hospital Base (CL), Swiss Academy of Medical Sciences (CH), Dassault Systèmes (Germany) (DE), Duke-NUS Medical School (SG)
Universität Basel
Openalex Percentile: Top 6%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.