Time-Domain Analysis of Rectangular Pulse Response in Capacitive Impedance Sensing Using Capacitively Coupled Contactless Electrodes

Impulse-based impedance sensing with capacitively coupled electrodes is introduced as a fast, non-contact, and simplified complementary method to conventional capacitive impedance measurements. Unlike frequency-domain methods, the proposed approach derives effective resistive and capacitive properties of a sample from the transient response to a single rectangular pulse. The equivalent circuit model comprises three elements: sample resistance, sample capacitance, and electrode coupling capacitance. From this model, analytical expressions of the transient response were derived, enabling accurate simulation of measured signals and providing the basis for both phantom verification and machine learning training. Importantly, the coupling capacitance, typically considered a limitation in contactless methods, is estimated alongside the sample parameters, providing insight into electrode–object coupling conditions. A machine-learning model trained on simulated circuit responses, including noise and temporal variability, is employed as a low-latency estimator for extracting parameters from measured transient signals. Experimental validation was carried out using a configurable lumped-element equivalent circuit and NaCl solutions of controlled conductivity, cross-verified with conductometric measurements and numerical probe simulations. Across a tested conductivity range, the method achieved estimation errors of 2–8%. The proposed approach is intended as a low-latency measurement strategy for simplified capacitively coupled impedance sensing, with potential relevance to future capacitively coupled electrical impedance tomography systems, where rapid acquisition of boundary measurements is prioritized over full frequency-resolved impedance spectroscopy.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-06-24
DOI
https://doi.org/10.3390/s26133999
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-Domain Analysis of Rectangular Pulse Response in Capacitive Impedance Sensing Using Capacitively Coupled Contactless Electrodes

Damian Wanta, Grzegorz Domański, Oliwia Makowiecka, M. Orzechowski et al.
Sensors
Electrical and Bioimpedance Tomography
article

Time-Domain Analysis of Rectangular Pulse Response in Capacitive Impedance Sensing Using Capacitively Coupled Contactless Electrodes

Damian Wanta, Grzegorz Domański, Oliwia Makowiecka, M. Orzechowski, Przemysław Wróblewski, Mikhail Ivanenko, Jacek Kryszyn, Waldemar T. Smolik, Mateusz Midura
article en

Abstract

Impulse-based impedance sensing with capacitively coupled electrodes is introduced as a fast, non-contact, and simplified complementary method to conventional capacitive impedance measurements. Unlike frequency-domain methods, the proposed approach derives effective resistive and capacitive properties of a sample from the transient response to a single rectangular pulse. The equivalent circuit model comprises three elements: sample resistance, sample capacitance, and electrode coupling capacitance. From this model, analytical expressions of the transient response were derived, enabling accurate simulation of measured signals and providing the basis for both phantom verification and machine learning training. Importantly, the coupling capacitance, typically considered a limitation in contactless methods, is estimated alongside the sample parameters, providing insight into electrode–object coupling conditions. A machine-learning model trained on simulated circuit responses, including noise and temporal variability, is employed as a low-latency estimator for extracting parameters from measured transient signals. Experimental validation was carried out using a configurable lumped-element equivalent circuit and NaCl solutions of controlled conductivity, cross-verified with conductometric measurements and numerical probe simulations. Across a tested conductivity range, the method achieved estimation errors of 2–8%. The proposed approach is intended as a low-latency measurement strategy for simplified capacitively coupled impedance sensing, with potential relevance to future capacitively coupled electrical impedance tomography systems, where rapid acquisition of boundary measurements is prioritized over full frequency-resolved impedance spectroscopy.

SensorsVol. 26(13)
Warsaw University of Technology (PL), Pit Radwar (Poland) (PL)
Politechnika Warszawska
Openalex Percentile: Top 10%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.