Assessment of Voltage Violation Risk in Distribution Networks Under Extreme High-Temperature Conditions with Multiphysics Field Coupling

To address the low-voltage violations that may occur in distribution networks with high penetration of distributed photovoltaic (PV) during sunset and evening peak periods under extreme high-temperature conditions, this paper establishes a source–grid–load electro-thermal coupling model that accounts for load thermal accumulation, transient conductor thermal inertia, temperature-dependent line impedance, and PV thermal derating. Based on a soft safety lower bound and a risk-preference utility function, the probability of voltage violation, violation depth, and expected violation duration are introduced to construct node-level and system-level comprehensive risk factors. The cumulant method combined with the Cornish–Fisher expansion is used to reconstruct the probability distribution of nodal voltages, enabling analytical risk calculation. Simulation results on the IEEE 33-bus system at 45 °C show that the proposed method can quantitatively reflect the temporal variations of nodal voltage distributions, physical violation depth, dimensionless severity utility, and expected violation duration, and identify weak nodes in the later part of the evening peak, providing a reference for risk early warning in distribution networks under extreme heat.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-06-24
DOI
https://doi.org/10.3390/en19132976
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Voltage Violation Risk in Distribution Networks Under Extreme High-Temperature Conditions with Multiphysics Field Coupling

Yifan Lv, Shuyi Wang, Hongwei Deng, Xiaoyu Nie et al.
Energies
Thermal Analysis in Power Transmission
article

Assessment of Voltage Violation Risk in Distribution Networks Under Extreme High-Temperature Conditions with Multiphysics Field Coupling

Yifan Lv, Shuyi Wang, Hongwei Deng, Xiaoyu Nie, Penghui Yan, Qinhua Chen, Jun He
article en

Abstract

To address the low-voltage violations that may occur in distribution networks with high penetration of distributed photovoltaic (PV) during sunset and evening peak periods under extreme high-temperature conditions, this paper establishes a source–grid–load electro-thermal coupling model that accounts for load thermal accumulation, transient conductor thermal inertia, temperature-dependent line impedance, and PV thermal derating. Based on a soft safety lower bound and a risk-preference utility function, the probability of voltage violation, violation depth, and expected violation duration are introduced to construct node-level and system-level comprehensive risk factors. The cumulant method combined with the Cornish–Fisher expansion is used to reconstruct the probability distribution of nodal voltages, enabling analytical risk calculation. Simulation results on the IEEE 33-bus system at 45 °C show that the proposed method can quantitatively reflect the temporal variations of nodal voltage distributions, physical violation depth, dimensionless severity utility, and expected violation duration, and identify weak nodes in the later part of the evening peak, providing a reference for risk early warning in distribution networks under extreme heat.

EnergiesVol. 19(13)
Hubei University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 8%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.