Comparison of alpha-particle track characteristics in GAGG and biological tissues for microdosimetry using experimentally validated GATE simulations with high-resolution track imaging

Abstract Objective. Real-time imaging of alpha-particle tracks in scintillators is promising for microdosimetric studies of alpha-emitting radionuclides in targeted radionuclide therapy. However, when inorganic scintillators such as Gd 3 Al 2 Ga 3 O 12 (GAGG) are used, the observed track characteristics differ from those in biological tissues. This study aimed to validate the GATE (geant4 application for tomographic emission) simulation framework using experimentally obtained alpha-particle track images and to compare track characteristics in GAGG and biological tissue-equivalent media. Such analysis is essential for quantitatively interpreting track images obtained with scintillator-based imaging systems in microdosimetry. Approach. Alpha-particle track images were obtained using a real-time high-resolution imaging system based on a GAGG scintillator and an Am-241 source. Simulated track ranges were compared with experimental images. The finalRange parameter in GATE was optimized because it affects the Bragg peak shape of alpha particles. Furthermore, simulated track characteristics in biological tissue-equivalent media were quantitatively compared with those in GAGG. Main Results. A bright endpoint artifact was identified in simulated alpha-particle tracks, originating from the particle transport mechanism implemented in Geant4/GATE and depending on the finalRange value. The simulated and experimental ranges of alpha particles in GAGG were 8.20 μ m and 8.05 μ m, respectively, demonstrating good agreement. Linear energy transfer (LET) values in GAGG were 2.8 and 1.8 times higher than those in adipose and bone, respectively. Significance. Recognizing this artifact is important for correct interpretation of LET distributions in microdosimetric evaluations. Our results demonstrated that GATE can accurately reproduce alpha-particle track characteristics and provides a useful framework for interpreting track structures observed in inorganic scintillators in terms of energy deposition in biological tissues. Nevertheless, optimization of the finalRange parameter is required for reliable microdosimetric evaluation.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-06-24
DOI
https://doi.org/10.1088/1361-6560/ae79cb
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of alpha-particle track characteristics in GAGG and biological tissues for microdosimetry using experimentally validated GATE simulations with high-resolution track imaging

Kenta Miwa, Kohei Nakanishi, Ryuichi Nishii, Masao Yoshino et al.
Physics in Medicine and Biology
Radiopharmaceutical Chemistry and Applications
article

Comparison of alpha-particle track characteristics in GAGG and biological tissues for microdosimetry using experimentally validated GATE simulations with high-resolution track imaging

Kenta Miwa, Kohei Nakanishi, Ryuichi Nishii, Masao Yoshino, Yuto Kamitaka, Seiichi Yamamoto, Noriaki Miyaji
article en

Abstract

Abstract Objective. Real-time imaging of alpha-particle tracks in scintillators is promising for microdosimetric studies of alpha-emitting radionuclides in targeted radionuclide therapy. However, when inorganic scintillators such as Gd 3 Al 2 Ga 3 O 12 (GAGG) are used, the observed track characteristics differ from those in biological tissues. This study aimed to validate the GATE (geant4 application for tomographic emission) simulation framework using experimentally obtained alpha-particle track images and to compare track characteristics in GAGG and biological tissue-equivalent media. Such analysis is essential for quantitatively interpreting track images obtained with scintillator-based imaging systems in microdosimetry. Approach. Alpha-particle track images were obtained using a real-time high-resolution imaging system based on a GAGG scintillator and an Am-241 source. Simulated track ranges were compared with experimental images. The finalRange parameter in GATE was optimized because it affects the Bragg peak shape of alpha particles. Furthermore, simulated track characteristics in biological tissue-equivalent media were quantitatively compared with those in GAGG. Main Results. A bright endpoint artifact was identified in simulated alpha-particle tracks, originating from the particle transport mechanism implemented in Geant4/GATE and depending on the finalRange value. The simulated and experimental ranges of alpha particles in GAGG were 8.20 μ m and 8.05 μ m, respectively, demonstrating good agreement. Linear energy transfer (LET) values in GAGG were 2.8 and 1.8 times higher than those in adipose and bone, respectively. Significance. Recognizing this artifact is important for correct interpretation of LET distributions in microdosimetric evaluations. Our results demonstrated that GATE can accurately reproduce alpha-particle track characteristics and provides a useful framework for interpreting track structures observed in inorganic scintillators in terms of energy deposition in biological tissues. Nevertheless, optimization of the finalRange parameter is required for reliable microdosimetric evaluation.

Physics in Medicine and BiologyVol. 71(12)
Fukushima Medical University (JP), Waseda University (JP), Tohoku University (JP), Nagoya University (JP)
Affordable and clean energy
Openalex Percentile: Top 7%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.