Diagnostic capability of ganglion cell complex thickness using spectral domain optical coherence tomography in glaucoma

BACKGROUND: This study had two main aims: first, aimed to document the normal values of macular ganglion cell complex (GCC) thickness among control eyes and glaucoma suspects and second, to evaluate the diagnostic ability of GCC parameters in distinguishing Primary Open Angle Glaucoma (POAG), Glaucoma Suspects and Controls in a tertiary eye centre in Nepal. METHODS: A hospital-based cross-sectional observational study was conducted in Kathmandu, Nepal, from June 2020 to June 2021. GCC parameters (Average GCC, Superior GCC, and Inferior GCC) were measured using spectral-domain Optical Coherence Tomography (OCT). These parameters were compared among groups using Linear Mixed-effect Models, considering considerable inter-eye correlation. Receiver operating characteristic (ROC) curves were constructed, and area under the curve (AUC) values were calculated to assess diagnostic performance. RESULTS: A total of 203 patients (406 eyes) were included - 76 with POAG, 62 Glaucoma suspects, and 65 Controls. Average GCC, superior GCC and Inferior GCC thickness were 96.54 ± 10.09 μm, 96.68 ± 10.91 μm and 96.43 ± 9.60 μm, in controls; 83.30 ± 11.46 μm, 83.88 ± 12.29 μm, and 81.94 ± 13.19 μm in POAG, and 93.76 ± 7.74 μm, 94.02 ± 8.03 μm, and 93.82 ± 8.27 μm, respectively in glaucoma suspects. All GCC parameters were significantly lower in the POAG group compared with both glaucoma suspects and controls (p < 0.05), even after adjustment for age. The highest diagnostic accuracy was observed for average GCC (AUC = 0.83, 95% C.I. - 0.77-0.92) and inferior GCC (AUC = 0.83, 95% C.I. - 0.76-0.90), both demonstrating excellent discrimination between POAG and controls (AUC = 0.83). CONCLUSIONS: All GCC parameters demonstrated a significant diagnostic capability in detecting POAG, with average GCC and inferior GCC thickness showing the best performance. The single-centre cross-sectional study design, and lack of randomisation were the main limitations of this study.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-06-24
DOI
https://doi.org/10.1186/s12886-026-05052-9
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic capability of ganglion cell complex thickness using spectral domain optical coherence tomography in glaucoma

Arika Poudel, Madhu Thapa, Pragati Gautam Adhikari, Ghimire Biplav
BMC Ophthalmology
Glaucoma and retinal disorders
article

Diagnostic capability of ganglion cell complex thickness using spectral domain optical coherence tomography in glaucoma

Arika Poudel, Madhu Thapa, Pragati Gautam Adhikari, Ghimire Biplav
article en

Abstract

BACKGROUND: This study had two main aims: first, aimed to document the normal values of macular ganglion cell complex (GCC) thickness among control eyes and glaucoma suspects and second, to evaluate the diagnostic ability of GCC parameters in distinguishing Primary Open Angle Glaucoma (POAG), Glaucoma Suspects and Controls in a tertiary eye centre in Nepal. METHODS: A hospital-based cross-sectional observational study was conducted in Kathmandu, Nepal, from June 2020 to June 2021. GCC parameters (Average GCC, Superior GCC, and Inferior GCC) were measured using spectral-domain Optical Coherence Tomography (OCT). These parameters were compared among groups using Linear Mixed-effect Models, considering considerable inter-eye correlation. Receiver operating characteristic (ROC) curves were constructed, and area under the curve (AUC) values were calculated to assess diagnostic performance. RESULTS: A total of 203 patients (406 eyes) were included - 76 with POAG, 62 Glaucoma suspects, and 65 Controls. Average GCC, superior GCC and Inferior GCC thickness were 96.54 ± 10.09 μm, 96.68 ± 10.91 μm and 96.43 ± 9.60 μm, in controls; 83.30 ± 11.46 μm, 83.88 ± 12.29 μm, and 81.94 ± 13.19 μm in POAG, and 93.76 ± 7.74 μm, 94.02 ± 8.03 μm, and 93.82 ± 8.27 μm, respectively in glaucoma suspects. All GCC parameters were significantly lower in the POAG group compared with both glaucoma suspects and controls (p < 0.05), even after adjustment for age. The highest diagnostic accuracy was observed for average GCC (AUC = 0.83, 95% C.I. - 0.77-0.92) and inferior GCC (AUC = 0.83, 95% C.I. - 0.76-0.90), both demonstrating excellent discrimination between POAG and controls (AUC = 0.83). CONCLUSIONS: All GCC parameters demonstrated a significant diagnostic capability in detecting POAG, with average GCC and inferior GCC thickness showing the best performance. The single-centre cross-sectional study design, and lack of randomisation were the main limitations of this study.

BMC Ophthalmology
Tribhuvan University (NP), Patan Hospital (NP), Kanti Children's Hospital (NP), Tribhuvan University Teaching Hospital (NP), Nepal Cancer Hospital and Research Center (NP)
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 6%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.