Measurements of radial angulation using computer-aided design software provide equal or superior reliability to multiplanar computed tomographic reconstruction in dogs

Objective: To compare CT measurements of radial geometry obtained using computer-aided design (CAD) software to those obtained using multiplanar reconstruction (MPR) and to compare their intraobserver reliability. We hypothesized that CAD and MPR measurements would be different and that the CAD method would have higher reliability. Methods: CT images from normal thoracic limbs of dogs scanned from January 1, 2018, through March 1, 2023, were retrospectively collected and analyzed. The CAD and MPR-based measurements in frontal (proximal/distal), sagittal, and torsional planes were made by 1 observer, in triplicate, and compared. Biases and reliability were calculated. Results: 10 right-sided thoracic limbs were included. Median proximal frontal angulation was 3.6° (IQR, -0.7° to 6.2°; valgus) using CAD and -6.8° (IQR, -8.9° to -5.3°; varus) using MPR. The reliability of CAD measurements of sagittal and distal frontal angulation was excellent, whereas the reliability of MPR measurements was moderate for sagittal angulation and poor for distal frontal angulation. There was no difference in reliability between CAD and MPR for proximal frontal or torsional measurements. Agreement between CAD and MPR was poor in all planes. Conclusions: Measurements of proximal frontal angulation differed between CAD and MPR groups, most likely due to differences in the anatomic features used. The reliability of CAD measurements was equal to or superior to the reliability of MPR measurements. Clinical Relevance: Understanding the relationship between CAD and MPR measurements is important as CAD-derived measurements are likely not equivalent to MPR-derived measurements.

Authors

Institutions

Publication Details

Journal
American Journal of Veterinary Research
Published
2026-06-24
DOI
https://doi.org/10.2460/ajvr.26.05.0205
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements of radial angulation using computer-aided design software provide equal or superior reliability to multiplanar computed tomographic reconstruction in dogs

Regan M. Stoneburner, Selena Tinga, Jason A. Bleedorn, Denis J. Marcellin‐Little et al.
American Journal of Veterinary Research
Veterinary Orthopedics and Neurology
article

Measurements of radial angulation using computer-aided design software provide equal or superior reliability to multiplanar computed tomographic reconstruction in dogs

Regan M. Stoneburner, Selena Tinga, Jason A. Bleedorn, Denis J. Marcellin‐Little, Lucas B. Lassinger, William M. Karlin, Galina Hayes
article en

Abstract

Objective: To compare CT measurements of radial geometry obtained using computer-aided design (CAD) software to those obtained using multiplanar reconstruction (MPR) and to compare their intraobserver reliability. We hypothesized that CAD and MPR measurements would be different and that the CAD method would have higher reliability. Methods: CT images from normal thoracic limbs of dogs scanned from January 1, 2018, through March 1, 2023, were retrospectively collected and analyzed. The CAD and MPR-based measurements in frontal (proximal/distal), sagittal, and torsional planes were made by 1 observer, in triplicate, and compared. Biases and reliability were calculated. Results: 10 right-sided thoracic limbs were included. Median proximal frontal angulation was 3.6° (IQR, -0.7° to 6.2°; valgus) using CAD and -6.8° (IQR, -8.9° to -5.3°; varus) using MPR. The reliability of CAD measurements of sagittal and distal frontal angulation was excellent, whereas the reliability of MPR measurements was moderate for sagittal angulation and poor for distal frontal angulation. There was no difference in reliability between CAD and MPR for proximal frontal or torsional measurements. Agreement between CAD and MPR was poor in all planes. Conclusions: Measurements of proximal frontal angulation differed between CAD and MPR groups, most likely due to differences in the anatomic features used. The reliability of CAD measurements was equal to or superior to the reliability of MPR measurements. Clinical Relevance: Understanding the relationship between CAD and MPR measurements is important as CAD-derived measurements are likely not equivalent to MPR-derived measurements.

American Journal of Veterinary Research
Tufts University (US), Hospital for Special Surgery (US), Cornell University (US), Dimension Technologies (United States) (US), University of California, Davis (US), Colorado State University (US)
No poverty
Openalex Percentile: Top 6%
Veterinary Orthopedics and Neurology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.