Surface wear and adhesive failure of resin attachments used in clear aligner therapy – a prospective study

Introduction & Aim Attachments are used in clear aligner therapy (CAT) to improve efficiency of tooth movement. This study was done to assess the surface wear and adhesive failure of conventional and optimized attachments used in CAT.Materials & Methods This prospective study recruited 13 participants with 211 resin attachments. Seventy-five teeth with conventional attachments (3 mm, 4 mm rectangular, ellipsoid) and 136 teeth with optimized attachments were scanned with iTero scanner. Meshmixer 3.5 was used to superimpose teeth bearing attachments initially (T1) with 3 month follow up scans (T2) based on best-fit registration. Deviation incidences were recorded. Adhesive failure of the attachments was also evaluated among the attachments.Statistical Analysis Shapiro–Wilk normality test, the Intraclass Correlation Coefficient (ICC), and Mann–Whitney test were employed.Conclusion Both attachment types showed no significant difference in wear after 3 months of CAT. A higher frequency of adhesive failure was observed in conventional attachments and in the upper molar region. However, given the observational study design, limited sample size and limitations pertaining to unit-of-analysis, these findings should be considered preliminary. The clinical significance of the observed wear patterns remains uncertain since treatment outcomes were not directly assessed.Results Deviations between samples were computed at 0.1 mm to 0.4 mm levels and revealed that both attachment types experienced similar amounts of wear after 3 months of aligner therapy. A higher frequency of adhesive failure was observed in conventional attachments and in the upper molar region. Surface wear was most frequently observed in upper anterior attachments.

Authors

Institutions

Publication Details

Journal
Clinical and Investigative Orthodontics
Published
2026-06-24
DOI
https://doi.org/10.1080/27705781.2026.2692817
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface wear and adhesive failure of resin attachments used in clear aligner therapy – a prospective study

Prateek Mehta, Nikhillesh Vaiid, Srirengalakshmi Muthuswamy Pandian, Aravind Kumar Subramanian et al.
Clinical and Investigative Orthodontics
Orthodontics and Dentofacial Orthopedics
article

Surface wear and adhesive failure of resin attachments used in clear aligner therapy – a prospective study

Prateek Mehta, Nikhillesh Vaiid, Srirengalakshmi Muthuswamy Pandian, Aravind Kumar Subramanian, S Jay Bowman, Ashish Kallur
article en

Abstract

Introduction & Aim Attachments are used in clear aligner therapy (CAT) to improve efficiency of tooth movement. This study was done to assess the surface wear and adhesive failure of conventional and optimized attachments used in CAT.Materials & Methods This prospective study recruited 13 participants with 211 resin attachments. Seventy-five teeth with conventional attachments (3 mm, 4 mm rectangular, ellipsoid) and 136 teeth with optimized attachments were scanned with iTero scanner. Meshmixer 3.5 was used to superimpose teeth bearing attachments initially (T1) with 3 month follow up scans (T2) based on best-fit registration. Deviation incidences were recorded. Adhesive failure of the attachments was also evaluated among the attachments.Statistical Analysis Shapiro–Wilk normality test, the Intraclass Correlation Coefficient (ICC), and Mann–Whitney test were employed.Conclusion Both attachment types showed no significant difference in wear after 3 months of CAT. A higher frequency of adhesive failure was observed in conventional attachments and in the upper molar region. However, given the observational study design, limited sample size and limitations pertaining to unit-of-analysis, these findings should be considered preliminary. The clinical significance of the observed wear patterns remains uncertain since treatment outcomes were not directly assessed.Results Deviations between samples were computed at 0.1 mm to 0.4 mm levels and revealed that both attachment types experienced similar amounts of wear after 3 months of aligner therapy. A higher frequency of adhesive failure was observed in conventional attachments and in the upper molar region. Surface wear was most frequently observed in upper anterior attachments.

Clinical and Investigative Orthodontics
King University (US), American Association of Orthodontists (US), Kingswood University (CA), Saint Louis University (US), Case Western Reserve University (US), Saveetha University (IN)
Openalex Percentile: Top 7%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.