Smartphone-based offline AI for multi-disease retinal screening: Real-world accuracy

ObjectiveTo evaluate the diagnostic accuracy of a multi-disease offline artificial intelligence system (Medios-AI, MAI), integrated into a smartphone-based fundus camera, for simultaneous screening of diabetic retinopathy (DR), glaucoma, and age-related macular degeneration (AMD) in a real-world setting.MethodsIn this prospective cross-sectional study, 193 adults (371 eyes) aged ≥18 years with DR, glaucoma, AMD, or normal fundus were enrolled between May and December 2024. Dilated fundus imaging was performed using the Remidio Fundus on Phone (FoP) and Zeiss Clarus 500 cameras. Ungradable images were excluded. The offline MAI algorithm generated disease-specific reports, which were compared to masked grading of Clarus images by two fellowship-trained ophthalmologists. In ambiguous cases, the AI report defaulted to "either DR or AMD."ResultsMAI achieved sensitivity of 99.3% (95% CI: 96-100), specificity of 95.7% (95% CI: 92-98), and AUROC of 0.99 for detecting any retinal disease. For glaucoma (n = 109), sensitivity was 98.2% (95% CI: 94-100), specificity 99.0% (95% CI: 97-100), AUROC 0.99. For AMD (n = 56), sensitivity was 88.9% (95% CI: 77-96), specificity 97.5% (95% CI: 95-99), AUROC 0.93. For DR (n = 78), sensitivity was 84.6% (95% CI: 75-92), specificity 99.0% (95% CI: 97-100), AUROC 0.92. Agreement on vertical cup-to-disc ratio between AI and graders ranged from -0.1 to +0.1, with intergrader ICC of 0.97 (P < 0.001 for all comparisons).ConclusionsMAI demonstrated significant diagnostic accuracy for DR, glaucoma, and AMD using an offline, smartphone-based platform, supporting scalable, point-of-care retinal screening in resource-limited settings.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2026-06-24
DOI
https://doi.org/10.1177/11206721261462321
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartphone-based offline AI for multi-disease retinal screening: Real-world accuracy

Aditya Kelkar, Harsh Jain, Sabyasachi Sengupta, Jai Kelkar et al.
European Journal of Ophthalmology
Retinal Imaging and Analysis
article

Smartphone-based offline AI for multi-disease retinal screening: Real-world accuracy

Aditya Kelkar, Harsh Jain, Sabyasachi Sengupta, Jai Kelkar, Yash Garg
article en

Abstract

ObjectiveTo evaluate the diagnostic accuracy of a multi-disease offline artificial intelligence system (Medios-AI, MAI), integrated into a smartphone-based fundus camera, for simultaneous screening of diabetic retinopathy (DR), glaucoma, and age-related macular degeneration (AMD) in a real-world setting.MethodsIn this prospective cross-sectional study, 193 adults (371 eyes) aged ≥18 years with DR, glaucoma, AMD, or normal fundus were enrolled between May and December 2024. Dilated fundus imaging was performed using the Remidio Fundus on Phone (FoP) and Zeiss Clarus 500 cameras. Ungradable images were excluded. The offline MAI algorithm generated disease-specific reports, which were compared to masked grading of Clarus images by two fellowship-trained ophthalmologists. In ambiguous cases, the AI report defaulted to "either DR or AMD."ResultsMAI achieved sensitivity of 99.3% (95% CI: 96-100), specificity of 95.7% (95% CI: 92-98), and AUROC of 0.99 for detecting any retinal disease. For glaucoma (n = 109), sensitivity was 98.2% (95% CI: 94-100), specificity 99.0% (95% CI: 97-100), AUROC 0.99. For AMD (n = 56), sensitivity was 88.9% (95% CI: 77-96), specificity 97.5% (95% CI: 95-99), AUROC 0.93. For DR (n = 78), sensitivity was 84.6% (95% CI: 75-92), specificity 99.0% (95% CI: 97-100), AUROC 0.92. Agreement on vertical cup-to-disc ratio between AI and graders ranged from -0.1 to +0.1, with intergrader ICC of 0.97 (P < 0.001 for all comparisons).ConclusionsMAI demonstrated significant diagnostic accuracy for DR, glaucoma, and AMD using an offline, smartphone-based platform, supporting scalable, point-of-care retinal screening in resource-limited settings.

European Journal of Ophthalmology
ViteroRetinal Surgery (US), Vasan Eye Care Hospital (IN)
Openalex Percentile: Top 7%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.