How I do it: a standardized robotic workflow for image-guided stereo-electroencephalography: technical description and institutional experience

BACKGROUND: Stereo-electroencephalography (SEEG) is a key technique for the presurgical evaluation of drug-resistant focal epilepsy [2]. Robotic assistance facilitates precise multi-trajectory stereotactic implantation and allows workflow standardization [1, 3, 5, 9]. We describe a reproducible image-based robotic SEEG implantation protocol and report our institutional experience. METHODS: An image-based robot-assisted SEEG technique using the Neuromate® system combined with intraoperative 3D imaging is presented. The workflow includes hypothesis-driven trajectory planning, alphabetical trajectory sequencing, laser-verified stereotactic registration, trajectory-specific skull thickness measurement with depth-controlled drilling, reducer-guided bolt placement, and intraoperative imaging verification. Institutional procedural data were reviewed to illustrate workflow performance and safety. RESULTS: Sixty-eight patients underwent implantation of 952 SEEG depth electrodes (mean 14 electrodes per patient). Mean robotic implantation time was 198 min (SD 54.9; range 80-280), corresponding to 14.1 min per electrode. Mean stereotactic registration error was 1.7 mm. Three patients (4.4%) developed intracranial hemorrhage, with one symptomatic case (1.47%) requiring surgical evacuation. This event occurred during electrode removal rather than implantation. No hemorrhage occurred during robotic electrode insertion, and no electrode repositioning or reintervention was required. CONCLUSION: Image-based robot-assisted SEEG enables accurate and reproducible multi-trajectory implantation with efficient workflow and low complication rates. Structured trajectory planning and systematic intraoperative verification may improve procedural safety and standardization.

Authors

Institutions

Publication Details

Journal
Acta Neurochirurgica
Published
2026-06-25
DOI
https://doi.org/10.1007/s00701-026-06937-w
Primary Topic
Epilepsy research and treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

How I do it: a standardized robotic workflow for image-guided stereo-electroencephalography: technical description and institutional experience

Jordi Rumià, Gloria Cabrera, P Gabriel Roldán, Alvaro Bedoya Gómez
Acta Neurochirurgica
Epilepsy research and treatment
article

How I do it: a standardized robotic workflow for image-guided stereo-electroencephalography: technical description and institutional experience

Jordi Rumià, Gloria Cabrera, P Gabriel Roldán, Alvaro Bedoya Gómez
article en

Abstract

BACKGROUND: Stereo-electroencephalography (SEEG) is a key technique for the presurgical evaluation of drug-resistant focal epilepsy [2]. Robotic assistance facilitates precise multi-trajectory stereotactic implantation and allows workflow standardization [1, 3, 5, 9]. We describe a reproducible image-based robotic SEEG implantation protocol and report our institutional experience. METHODS: An image-based robot-assisted SEEG technique using the Neuromate® system combined with intraoperative 3D imaging is presented. The workflow includes hypothesis-driven trajectory planning, alphabetical trajectory sequencing, laser-verified stereotactic registration, trajectory-specific skull thickness measurement with depth-controlled drilling, reducer-guided bolt placement, and intraoperative imaging verification. Institutional procedural data were reviewed to illustrate workflow performance and safety. RESULTS: Sixty-eight patients underwent implantation of 952 SEEG depth electrodes (mean 14 electrodes per patient). Mean robotic implantation time was 198 min (SD 54.9; range 80-280), corresponding to 14.1 min per electrode. Mean stereotactic registration error was 1.7 mm. Three patients (4.4%) developed intracranial hemorrhage, with one symptomatic case (1.47%) requiring surgical evacuation. This event occurred during electrode removal rather than implantation. No hemorrhage occurred during robotic electrode insertion, and no electrode repositioning or reintervention was required. CONCLUSION: Image-based robot-assisted SEEG enables accurate and reproducible multi-trajectory implantation with efficient workflow and low complication rates. Structured trajectory planning and systematic intraoperative verification may improve procedural safety and standardization.

Acta Neurochirurgica
Hospital Clínic de Barcelona (ES), Universitat de Barcelona (ES)
Universitat de Barcelona
Openalex Percentile: Top 8%
Epilepsy research and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.