Stepwise calibration method for the overview camera of an image-assisted total station

Combining total station and camera, the system measures large dynamic objects. Current calibration mainly covers coaxial and external cameras, lacking research on the vital built-in overview camera of image-assisted total stations. This paper builds its image measurement model and develops overall and stepwise calibration methods. The overall method is unstable and range-limited, whereas stepwise calibration achieves effective parameter decoupling. On this basis, fourth-order bivariate Fourier APs are used for distortion compensation. After correction, MAE and Std reach 0.07 and 0.09 pixels in both x and y directions, offering reliable references for practical calibration.

Authors

Institutions

Publication Details

Journal
Survey Review
Published
2026-06-17
DOI
https://doi.org/10.1080/00396265.2026.2684302
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stepwise calibration method for the overview camera of an image-assisted total station

C.-L. Ruan, Houtian Zhang, Shaojie Chen, Chonghui Li et al.
Survey Review
Optical measurement and interference techniques
article

Stepwise calibration method for the overview camera of an image-assisted total station

C.-L. Ruan, Houtian Zhang, Shaojie Chen, Chonghui Li, Shuai Tong
article en

Abstract

Combining total station and camera, the system measures large dynamic objects. Current calibration mainly covers coaxial and external cameras, lacking research on the vital built-in overview camera of image-assisted total stations. This paper builds its image measurement model and develops overall and stepwise calibration methods. The overall method is unstable and range-limited, whereas stepwise calibration achieves effective parameter decoupling. On this basis, fourth-order bivariate Fourier APs are used for distortion compensation. After correction, MAE and Std reach 0.07 and 0.09 pixels in both x and y directions, offering reliable references for practical calibration.

Survey Review
Geospatial Research (United Kingdom) (GB), Luoyang Institute of Science and Technology (CN)
Openalex Percentile: Top 4%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.