Endoscopic detection of near-infrared autofluorescence in the parathyroid glands: a case report of two patients

Introduction and importance: Preservation of the parathyroid glands during thyroid surgery is crucial to prevent postoperative hypocalcemia. Parathyroid glands exhibit intrinsic autofluorescence with an emission peak around 820 nm, and near-infrared imaging has been applied for their intraoperative identification. However, its feasibility in endoscopic thyroid surgery remains unclear, particularly when using a small-diameter endoscope. Here, we report two cases in which parathyroid autofluorescence was successfully visualized during endoscopic surgery using a 5-mm endoscope. Case presentation: The first patient was a 75-year-old woman with breast cancer who was referred to us with a right thyroid nodule detected on preoperative positron emission tomography/computed tomography. Fine-needle aspiration cytology suggested papillary carcinoma, and as the nodule gradually enlarged, we performed a right thyroid lobectomy after 7 years using video-assisted neck surgery (VANS) with a 5-mm endoscope. A parathyroid gland on the posterior thyroid surface showed homogeneous and strong autofluorescence. The second patient was a 53-year-old woman with primary hyperparathyroidism who presented with hypercalcemia and elevated intact parathormone levels. We performed a right parathyroidectomy using VANS with the same endoscope. A parathyroid tumor showing heterogeneous and relatively weak autofluorescence was identified on the posterior aspect of the right thyroid lobe. Clinical discussion: In both cases, near-infrared imaging revealed parathyroid autofluorescence during VANS. Adequate display settings, including enhanced brightness and contrast, appear to be important for clear visualization. Conclusion: Parathyroid autofluorescence can be visualized even during endoscopic thyroid surgery with a 5-mm endoscope and may contribute to safer procedures.

Authors

Institutions

Publication Details

Journal
Annals of Medicine and Surgery
Published
2026-06-18
DOI
https://doi.org/10.1097/ms9.0000000000005247
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endoscopic detection of near-infrared autofluorescence in the parathyroid glands: a case report of two patients

Kazuchika Ohno, Ryuhei Okada, Takahiro Asakage, Iichiroh Onishi
Annals of Medicine and Surgery
Thyroid and Parathyroid Surgery
article

Endoscopic detection of near-infrared autofluorescence in the parathyroid glands: a case report of two patients

Kazuchika Ohno, Ryuhei Okada, Takahiro Asakage, Iichiroh Onishi
article en

Abstract

Introduction and importance: Preservation of the parathyroid glands during thyroid surgery is crucial to prevent postoperative hypocalcemia. Parathyroid glands exhibit intrinsic autofluorescence with an emission peak around 820 nm, and near-infrared imaging has been applied for their intraoperative identification. However, its feasibility in endoscopic thyroid surgery remains unclear, particularly when using a small-diameter endoscope. Here, we report two cases in which parathyroid autofluorescence was successfully visualized during endoscopic surgery using a 5-mm endoscope. Case presentation: The first patient was a 75-year-old woman with breast cancer who was referred to us with a right thyroid nodule detected on preoperative positron emission tomography/computed tomography. Fine-needle aspiration cytology suggested papillary carcinoma, and as the nodule gradually enlarged, we performed a right thyroid lobectomy after 7 years using video-assisted neck surgery (VANS) with a 5-mm endoscope. A parathyroid gland on the posterior thyroid surface showed homogeneous and strong autofluorescence. The second patient was a 53-year-old woman with primary hyperparathyroidism who presented with hypercalcemia and elevated intact parathormone levels. We performed a right parathyroidectomy using VANS with the same endoscope. A parathyroid tumor showing heterogeneous and relatively weak autofluorescence was identified on the posterior aspect of the right thyroid lobe. Clinical discussion: In both cases, near-infrared imaging revealed parathyroid autofluorescence during VANS. Adequate display settings, including enhanced brightness and contrast, appear to be important for clear visualization. Conclusion: Parathyroid autofluorescence can be visualized even during endoscopic thyroid surgery with a 5-mm endoscope and may contribute to safer procedures.

Annals of Medicine and Surgery
Tokyo Institute of Technology (JP), Tokyo Institute of Psychiatry (JP), Institute of Science Tokyo (JP)
Good health and well-being
Openalex Percentile: Top 5%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.