Is Fibrin a Suitable Matrix for Small-Diameter Bioartificial Vascular Grafts? An In Vitro Short-Term Hemocompatibility Study

Background: The generation of durable and hemocompatible small-diameter vascular grafts remains a major challenge in current vascular tissue engineering, as clinically available synthetic grafts are lacking hemocompatibility resulting in limited long-term patency. In recent years, fibrin has emerged as a promising scaffold material for various tissue engineering approaches due to its autologous nature, controllable fabrication, and mechanical properties. However, although pivotal for the translation into clinical application, systematic evaluation of hemocompatibility in fibrin-based small-caliber grafts is still missing. Methods: Here, the hemocompatibility of small-diameter fibrin-based grafts with and without heparin coating was compared to the current gold standard for prosthetic small-diameter vessel replacement in the form of heparin-coated ePTFE grafts using the Chandler Loop circulation model with human whole blood. Cell adhesion of thrombocytes, erythrocytes, and leucocytes was compared. Platelet activation, activation of the complement system, and plasmatic coagulation activity were assessed by ELISA analyses for P-Selectin, complement sC5b-9, and thrombin–antithrombin complex, respectively. Scanning electron microscopy (SEM) was performed to evaluate interactions and thrombocyte activation on the luminal graft surfaces. Results: The short-term hemocompatibility of the fibrin-based grafts with respect to the cell-count, activation of the coagulation pathways, and thrombocyte activation was comparable to the heparin-coated synthetic grafts even without heparin coating of the bioartificial grafts. Conclusions: The findings of this early-stage analysis support fibrin as a promising scaffold material for small-diameter vascular tissue engineering.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-06-18
DOI
https://doi.org/10.3390/jfb17060303
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is Fibrin a Suitable Matrix for Small-Diameter Bioartificial Vascular Grafts? An In Vitro Short-Term Hemocompatibility Study

Florian Helms, Arjang Ruhparwar, Patrick Stadler, Michael Pflaum et al.
Journal of Functional Biomaterials
Electrospun Nanofibers in Biomedical Applications
article

Is Fibrin a Suitable Matrix for Small-Diameter Bioartificial Vascular Grafts? An In Vitro Short-Term Hemocompatibility Study

Florian Helms, Arjang Ruhparwar, Patrick Stadler, Michael Pflaum, Clara Glomb, Melanie Klingenberg, Mathias Wilhelmi
article en

Abstract

Background: The generation of durable and hemocompatible small-diameter vascular grafts remains a major challenge in current vascular tissue engineering, as clinically available synthetic grafts are lacking hemocompatibility resulting in limited long-term patency. In recent years, fibrin has emerged as a promising scaffold material for various tissue engineering approaches due to its autologous nature, controllable fabrication, and mechanical properties. However, although pivotal for the translation into clinical application, systematic evaluation of hemocompatibility in fibrin-based small-caliber grafts is still missing. Methods: Here, the hemocompatibility of small-diameter fibrin-based grafts with and without heparin coating was compared to the current gold standard for prosthetic small-diameter vessel replacement in the form of heparin-coated ePTFE grafts using the Chandler Loop circulation model with human whole blood. Cell adhesion of thrombocytes, erythrocytes, and leucocytes was compared. Platelet activation, activation of the complement system, and plasmatic coagulation activity were assessed by ELISA analyses for P-Selectin, complement sC5b-9, and thrombin–antithrombin complex, respectively. Scanning electron microscopy (SEM) was performed to evaluate interactions and thrombocyte activation on the luminal graft surfaces. Results: The short-term hemocompatibility of the fibrin-based grafts with respect to the cell-count, activation of the coagulation pathways, and thrombocyte activation was comparable to the heparin-coated synthetic grafts even without heparin coating of the bioartificial grafts. Conclusions: The findings of this early-stage analysis support fibrin as a promising scaffold material for small-diameter vascular tissue engineering.

Journal of Functional BiomaterialsVol. 17(6)
Medizinische Hochschule Hannover (DE), St. Bernward Krankenhaus (DE)
Openalex Percentile: Top 12%
Electrospun Nanofibers in Biomedical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.