Nontargeted Calibration: A Novel Method for Understanding Uptake Kinetics of Diverse Compounds Using Passive Air Samplers

Conventional calibration of passive air samplers (PASs) is limited by the accessibility of analytical standards required for quantifying mass in targeted analysis. Here, we introduce a method using relative peak areas measured with nontargeted analysis to approximate PAS uptake rates for diverse features. We tested the approach with mesh-sheltered polydimethylsiloxane (PDMS) foam and glass fiber filter (GFF) PASs. Generic uptake rates were 1.16 ± 0.34 m 3 day –1 dm –2 for 67 features measured in PDMS foam and 0.50 ± 0.33 m 3 day –1 dm –2 for 48 features measured in GFF, comparable to uptake rates from the targeted calibration literature. The generic uptake rate for PDMS-Mesh showed low variability (relative standard deviation─RSD = 29%) with no relationship to predicted physical–chemical properties. The generic rate for GFF-Mesh was instead 0.61 ± 0.20 m 3 day –1 dm –2 when including only features with predicted log octanol-air partition ratios (K OA s) < 8.5 log units, showing decreased variability (from 66% to 32% RSD). Specific uptake rates should be used for features with K OA s > 8.5 log units measured on GFF-Mesh. Our results demonstrate that nontargeted calibration can characterize PAS uptake for diverse compounds comparably to targeted calibration, which will expand our understanding of uptake kinetics without requiring analytical standards.

Authors

Institutions

Publication Details

Journal
ACS ES&T Air
Published
2026-06-18
DOI
https://doi.org/10.1021/acsestair.6c00185
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nontargeted Calibration: A Novel Method for Understanding Uptake Kinetics of Diverse Compounds Using Passive Air Samplers

Anping Guo, Joseph O. Okeme, Celine Su, Alyss S.V. McPherson et al.
ACS ES&T Air
Indoor Air Quality and Microbial Exposure
article

Nontargeted Calibration: A Novel Method for Understanding Uptake Kinetics of Diverse Compounds Using Passive Air Samplers

Anping Guo, Joseph O. Okeme, Celine Su, Alyss S.V. McPherson, Ellie Davies
article en

Abstract

Conventional calibration of passive air samplers (PASs) is limited by the accessibility of analytical standards required for quantifying mass in targeted analysis. Here, we introduce a method using relative peak areas measured with nontargeted analysis to approximate PAS uptake rates for diverse features. We tested the approach with mesh-sheltered polydimethylsiloxane (PDMS) foam and glass fiber filter (GFF) PASs. Generic uptake rates were 1.16 ± 0.34 m 3 day –1 dm –2 for 67 features measured in PDMS foam and 0.50 ± 0.33 m 3 day –1 dm –2 for 48 features measured in GFF, comparable to uptake rates from the targeted calibration literature. The generic uptake rate for PDMS-Mesh showed low variability (relative standard deviation─RSD = 29%) with no relationship to predicted physical–chemical properties. The generic rate for GFF-Mesh was instead 0.61 ± 0.20 m 3 day –1 dm –2 when including only features with predicted log octanol-air partition ratios (K OA s) < 8.5 log units, showing decreased variability (from 66% to 32% RSD). Specific uptake rates should be used for features with K OA s > 8.5 log units measured on GFF-Mesh. Our results demonstrate that nontargeted calibration can characterize PAS uptake for diverse compounds comparably to targeted calibration, which will expand our understanding of uptake kinetics without requiring analytical standards.

ACS ES&T Air
McMaster University (CA)
Openalex Percentile: Top 7%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nontargeted Calibration: A Novel Method for Understanding Uptake Kinetics of Diverse Compounds Using Passive Air Samplers — Anping Guo, Joseph O. Okeme, et al. · ACS ES&T Air (2026) | TGRS Research Map | TGRS