Diagnostic Accuracy of PET Imaging for Lymph Node Detection in Breast cancer patients undergoing Upfront Surgery: A Single-Institution Analysis of Breast Cancer Patients

<ns5:p>Background The role of PET imaging in lymph node staging for breast cancer patients proceeding to upfront surgery remains incompletely characterized. We evaluated the diagnostic accuracy of PET imaging in immediate surgical patients. Methods A retrospective cohort of 70 breast cancer patients undergoing upfront surgery was analyzed. PET imaging findings were compared with histopathological examination (HPE) results. Diagnostic accuracy metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios were calculated. Results Among 70 surgical patients (mean age 53.9 ± 11.5 years), 26 (37.14%) had pathologically confirmed lymph node involvement. PET imaging demonstrated sensitivity of 69.23% (95% CI: 48.27-85.67), specificity of 81.82% (95% CI: 67.27-91.60), PPV of 69.23%, and NPV of 81.82%. The test correctly identified 18 of 26 patients with nodal disease while avoiding false positives in 36 of 44 node-negative patients. Positive likelihood ratio was 3.81, and negative likelihood ratio was 0.38. The F1-score was 0.6923, indicating good balance between precision and sensitivity for surgical planning. Conclusions PET imaging demonstrated moderate sensitivity (69.23%) for detecting lymph node involvement in patients undergoing upfront surgery. Its relatively high negative predictive value (81.82%) suggests a potential role in identifying patients at lower risk of nodal disease; however, negative PET findings should be interpreted in conjunction with clinical, radiological, and pathological assessment. PET may contribute to preoperative staging and surgical planning, while positive findings may require confirmatory evaluation when management decisions depend on nodal status.</ns5:p>

Authors

Institutions

Publication Details

Journal
F1000Research
Published
2026-06-18
DOI
https://doi.org/10.12688/f1000research.177892.3
Primary Topic
Breast Cancer Treatment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of PET Imaging for Lymph Node Detection in Breast cancer patients undergoing Upfront Surgery: A Single-Institution Analysis of Breast Cancer Patients

Rohan Shetty, Sarath Chandu Yadlapalli, Vijayakumar M
F1000Research
Breast Cancer Treatment Studies
article

Diagnostic Accuracy of PET Imaging for Lymph Node Detection in Breast cancer patients undergoing Upfront Surgery: A Single-Institution Analysis of Breast Cancer Patients

Rohan Shetty, Sarath Chandu Yadlapalli, Vijayakumar M
article en

Abstract

<ns5:p>Background The role of PET imaging in lymph node staging for breast cancer patients proceeding to upfront surgery remains incompletely characterized. We evaluated the diagnostic accuracy of PET imaging in immediate surgical patients. Methods A retrospective cohort of 70 breast cancer patients undergoing upfront surgery was analyzed. PET imaging findings were compared with histopathological examination (HPE) results. Diagnostic accuracy metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios were calculated. Results Among 70 surgical patients (mean age 53.9 ± 11.5 years), 26 (37.14%) had pathologically confirmed lymph node involvement. PET imaging demonstrated sensitivity of 69.23% (95% CI: 48.27-85.67), specificity of 81.82% (95% CI: 67.27-91.60), PPV of 69.23%, and NPV of 81.82%. The test correctly identified 18 of 26 patients with nodal disease while avoiding false positives in 36 of 44 node-negative patients. Positive likelihood ratio was 3.81, and negative likelihood ratio was 0.38. The F1-score was 0.6923, indicating good balance between precision and sensitivity for surgical planning. Conclusions PET imaging demonstrated moderate sensitivity (69.23%) for detecting lymph node involvement in patients undergoing upfront surgery. Its relatively high negative predictive value (81.82%) suggests a potential role in identifying patients at lower risk of nodal disease; however, negative PET findings should be interpreted in conjunction with clinical, radiological, and pathological assessment. PET may contribute to preoperative staging and surgical planning, while positive findings may require confirmatory evaluation when management decisions depend on nodal status.</ns5:p>

F1000ResearchVol. 15
Yenepoya University (IN)
Good health and well-being
Openalex Percentile: Top 7%
Breast Cancer Treatment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnostic Accuracy of PET Imaging for Lymph Node Detection in Breast cancer patients undergoing Upfront Surgery: A Single-Institution Analysis of Breast Cancer Patients — Rohan Shetty, Sarath Chandu Yadlapalli, et al. · F1000Research (2026) | TGRS Research Map | TGRS