Improved pancreatic imaging with photon-counting CT: a retrospective comparison with conventional CT

Background Imaging is crucial for the detection of pancreatic diseases. Photon-counting computed tomography (PCCT) is a recent improvement in CT detector technology that may improve pancreatic imaging quality. Purpose To compare the image quality in pancreatic imaging with PCCT versus conventional CT (EIDCT) both subjectively and quantitatively. Material and Methods We retrospectively identified 35 patients scanned with both EIDCT and PCCT in multiple contrast phases. Image quality over 11 peripancreatic areas was rated on a 5-point Likert scale. One reader made quantitative measurements of density and noise. Data analysis was performed using R Studio. Continuous data were compared using a paired t -test and ordinal data with a Wilcoxon signed-rank test. Results Image quality was rated significantly higher on PCCT for the pancreatic parenchyma in the late arterial phase (3.87 vs. 2.77; P <0.01), the pancreatic parenchyma in the portal venous phase (3.31 vs. 2.53; P <0.01), pancreatic ducts (2.88 vs. 2.62; P <0.01), superior mesenteric artery (4.10 vs. 2.74; P <0.01), coeliac axis (4.04 vs. 2.70; P <0.01), and portal vein (3.29 vs. 2.52; P <0.01). Noise levels were significantly lower with PCCT with a mean reduction of 5.8 HU across all areas. Dose-length-product was significantly reduced in both the late arterial phase (31.8%; P <0.01) and the portal venous phase (21.5%; P <0.01). Conclusion Image quality was subjectively and quantitatively significantly improved for all evaluated pancreatic and peripancreatic structures with PCCT compared to EIDCT. In addition, radiation dose was significantly reduced.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2026-06-18
DOI
https://doi.org/10.1177/02841851261458363
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved pancreatic imaging with photon-counting CT: a retrospective comparison with conventional CT

Michael Brun Andersen, Erik Brandt, Henrik S. Thomsen, Yousef JW Nielsen et al.
Acta Radiologica
Advanced X-ray and CT Imaging
article

Improved pancreatic imaging with photon-counting CT: a retrospective comparison with conventional CT

Michael Brun Andersen, Erik Brandt, Henrik S. Thomsen, Yousef JW Nielsen, Anders Rodell, Anne Marie Ewald, Felix Christoph Müller, Bulat Ibragimov
article en

Abstract

Background Imaging is crucial for the detection of pancreatic diseases. Photon-counting computed tomography (PCCT) is a recent improvement in CT detector technology that may improve pancreatic imaging quality. Purpose To compare the image quality in pancreatic imaging with PCCT versus conventional CT (EIDCT) both subjectively and quantitatively. Material and Methods We retrospectively identified 35 patients scanned with both EIDCT and PCCT in multiple contrast phases. Image quality over 11 peripancreatic areas was rated on a 5-point Likert scale. One reader made quantitative measurements of density and noise. Data analysis was performed using R Studio. Continuous data were compared using a paired t -test and ordinal data with a Wilcoxon signed-rank test. Results Image quality was rated significantly higher on PCCT for the pancreatic parenchyma in the late arterial phase (3.87 vs. 2.77; P <0.01), the pancreatic parenchyma in the portal venous phase (3.31 vs. 2.53; P <0.01), pancreatic ducts (2.88 vs. 2.62; P <0.01), superior mesenteric artery (4.10 vs. 2.74; P <0.01), coeliac axis (4.04 vs. 2.70; P <0.01), and portal vein (3.29 vs. 2.52; P <0.01). Noise levels were significantly lower with PCCT with a mean reduction of 5.8 HU across all areas. Dose-length-product was significantly reduced in both the late arterial phase (31.8%; P <0.01) and the portal venous phase (21.5%; P <0.01). Conclusion Image quality was subjectively and quantitatively significantly improved for all evaluated pancreatic and peripancreatic structures with PCCT compared to EIDCT. In addition, radiation dose was significantly reduced.

Acta Radiologica
University of Copenhagen (DK), Copenhagen University Hospital (DK), Siemens (Denmark) (DK)
Openalex Percentile: Top 11%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.