From perception to imagination: a robust deep learning architecture for real-time EEG decoding and neurophysiological validation

BCI clinical viability is hindered by “BCI illiteracy” (15–30% failure rate) and high latency. We propose CSOANet2026, a lightweight CNN with a FIR/ICA preprocessing pipeline, evaluated on 46 subjects. The 3,028-parameter model: (1) reaches 98.67% ± 2.46% within-subject accuracy and 96.73% ± 6.31% leave-one-subject-out (LOSO) accuracy, recovering decoding for “noisy” subjects who fail under linear baselines; (2) runs in 3.99 ± 0.60 ms (CPU)/0.81 ± 0.16 ms (GPU) per trial with a ~17 KB memory footprint; and (3) uses Grad-CAM and gate-weight analyses to verify reliance on neurophysiologically valid occipital Alpha-band (10–13 Hz) modulation—suppression during perception and synchronization during imagery. CSOANet2026 occupies a Pareto-optimal point of the accuracy–capacity frontier, matching deeper CNN baselines at 1/40 to 1/105 of their parameter count, while meeting real-time constraints for closed-loop neurofeedback.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization
Published
2026-06-18
DOI
https://doi.org/10.1080/21681163.2026.2684109
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From perception to imagination: a robust deep learning architecture for real-time EEG decoding and neurophysiological validation

José Miguel Diniz, Yu Gao
Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization
EEG and Brain-Computer Interfaces
article

From perception to imagination: a robust deep learning architecture for real-time EEG decoding and neurophysiological validation

José Miguel Diniz, Yu Gao
article en

Abstract

BCI clinical viability is hindered by “BCI illiteracy” (15–30% failure rate) and high latency. We propose CSOANet2026, a lightweight CNN with a FIR/ICA preprocessing pipeline, evaluated on 46 subjects. The 3,028-parameter model: (1) reaches 98.67% ± 2.46% within-subject accuracy and 96.73% ± 6.31% leave-one-subject-out (LOSO) accuracy, recovering decoding for “noisy” subjects who fail under linear baselines; (2) runs in 3.99 ± 0.60 ms (CPU)/0.81 ± 0.16 ms (GPU) per trial with a ~17 KB memory footprint; and (3) uses Grad-CAM and gate-weight analyses to verify reliance on neurophysiologically valid occipital Alpha-band (10–13 Hz) modulation—suppression during perception and synchronization during imagery. CSOANet2026 occupies a Pareto-optimal point of the accuracy–capacity frontier, matching deeper CNN baselines at 1/40 to 1/105 of their parameter count, while meeting real-time constraints for closed-loop neurofeedback.

Computer Methods in Biomechanics and Biomedical Engineering Imaging & VisualizationVol. 14(1)
Universidade do Porto (PT), Embedded Systems (United States) (US)
Quality Education
Openalex Percentile: Top 5%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.