Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs

Abstract Purpose Traditionally, interbody cages feature a central cavity for graft packing. However, for bioactive glass-ceramic (BGS-7) spacers achieving fusion via surface-mediated osseointegration, this cavity may be biologically redundant and structurally disadvantageous. We compared radiological and clinical outcomes of plated anterior cervical discectomy and fusion (ACDF) using BGS-7 spacers with or without a central cavity. Methods We retrospectively reviewed patients undergoing plated ACDF using solid non-cavity (17 patients, 24 levels) or central-cavity (17 patients, 33 levels) BGS-7 spacers. Radiographic fusion was evaluated using dynamic interspinous distance (primary, ≤ 2 mm) and segmental angular motion (secondary, ≤ 4°), alongside CT-based osseointegration (direct contact ≥ 50%). Subsidence (≥ 2 mm) and clinical outcomes were evaluated at 12 months. Results Both groups demonstrated comparable 12-month clinical improvements ( p > 0.05). Radiographic fusion rates were equivalent between non-cavity and central-cavity groups based on the primary distance (91.7% vs. 84.8%, p = 0.687) and secondary angular criteria (79.2% vs. 63.6%, p = 0.331). The non-cavity group showed a trend toward superior segmental stability, with a smaller dynamic gap distance (0.82 ± 0.64 mm vs. 1.53 ± 1.99 mm, p = 0.064). CT-based fusion perfectly matched (90.5% vs. 90.9%, p = 1.000). Subsidence rates were comparably low (12.5% vs. 12.1%), with no spacer breakage. Conclusions In plated ACDF, adding a central cavity to BGS-7 spacers confers no measurable advantage over the solid design. Solid spacers inherently preserve maximum endplate contact area for optimal load-sharing and surface-mediated fusion. Eliminating the cavity and supplemental grafts avoids logical redundancy, donor-site morbidity, and unnecessary healthcare costs.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-06-18
DOI
https://doi.org/10.1007/s00402-026-06389-y
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs

Tae Hoon Kang, Byungjun Kang, Jae Hyup Lee, Ji-Sun Han et al.
Archives of Orthopaedic and Trauma Surgery
Cervical and Thoracic Myelopathy
article

Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs

Tae Hoon Kang, Byungjun Kang, Jae Hyup Lee, Ji-Sun Han, Geumho Lee, Minjoon Cho
article en

Abstract

Abstract Purpose Traditionally, interbody cages feature a central cavity for graft packing. However, for bioactive glass-ceramic (BGS-7) spacers achieving fusion via surface-mediated osseointegration, this cavity may be biologically redundant and structurally disadvantageous. We compared radiological and clinical outcomes of plated anterior cervical discectomy and fusion (ACDF) using BGS-7 spacers with or without a central cavity. Methods We retrospectively reviewed patients undergoing plated ACDF using solid non-cavity (17 patients, 24 levels) or central-cavity (17 patients, 33 levels) BGS-7 spacers. Radiographic fusion was evaluated using dynamic interspinous distance (primary, ≤ 2 mm) and segmental angular motion (secondary, ≤ 4°), alongside CT-based osseointegration (direct contact ≥ 50%). Subsidence (≥ 2 mm) and clinical outcomes were evaluated at 12 months. Results Both groups demonstrated comparable 12-month clinical improvements ( p > 0.05). Radiographic fusion rates were equivalent between non-cavity and central-cavity groups based on the primary distance (91.7% vs. 84.8%, p = 0.687) and secondary angular criteria (79.2% vs. 63.6%, p = 0.331). The non-cavity group showed a trend toward superior segmental stability, with a smaller dynamic gap distance (0.82 ± 0.64 mm vs. 1.53 ± 1.99 mm, p = 0.064). CT-based fusion perfectly matched (90.5% vs. 90.9%, p = 1.000). Subsidence rates were comparably low (12.5% vs. 12.1%), with no spacer breakage. Conclusions In plated ACDF, adding a central cavity to BGS-7 spacers confers no measurable advantage over the solid design. Solid spacers inherently preserve maximum endplate contact area for optimal load-sharing and surface-mediated fusion. Eliminating the cavity and supplemental grafts avoids logical redundancy, donor-site morbidity, and unnecessary healthcare costs.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
New Generation University College (ET), SNUH SMG-SNU Boramae Medical Center (KR), Sungae Hospital (KR), The Catholic University of Korea Bucheon St. Mary's Hospital (KR), Incheon Medical Center (KR)
Openalex Percentile: Top 5%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.