Advanced systems for intraoperative cartilage evaluation and treatment demonstrate early feasibility and a shift towards integrating artificial intelligence: A scoping review
PURPOSE: To review the current literature evaluating AI and advanced technologies for intraoperative cartilage management. METHODS: A comprehensive search of PubMed, Embase, and Scopus was conducted in March 2026 according to PRISMA guidelines. Eligible studies included cadaveric, in-vivo, or clinical investigations using AI-based or computer navigation systems for real-time intraoperative diagnosis, mapping, or treatment of cartilage lesions. Studies limited to preoperative planning, static imaging segmentation, or non-surgical applications were excluded. Two reviewers screened studies, extracted data on design, population, technology type, and outcomes, and assessed risk of bias using CLAIM, QUADAS-2, or MINORS criteria. Findings were synthesised narratively. RESULTS: Seven studies met inclusion criteria. These included three studies evaluating AI-based cartilage mapping and segmentation systems, three assessing computer-assisted navigation systems, and one describing a hybrid system integrating mapping with navigation. AI-based segmentation and mapping systems demonstrated Dice coefficients of 0.68-0.90 and intersection-over-union scores up to 92%, with performance comparable to human reference masks but reduced accuracy in low-quality images. Navigation systems for osteochondral grafting reduced angular errors in graft harvest, coring, and placement from >12° freehand to <4° with navigation, and hybrid systems decreased plug orientation error from 15.4° to 6.5°. Stereo-endoscopic platforms achieved sub-millimetre 3D reconstruction but exceeded clinically acceptable orientation thresholds. Intraoperative 3D laser scanning achieved mean defect measurement error of 0.46 mm and reduced workflow times to <4 min compared with approximately 15 min conventionally. CONCLUSION: Early studies support the feasibility and accuracy of computer-assisted and navigation-based technologies, as well as AI-driven mapping, for real-time cartilage assessment and treatment. Further clinical evaluation is needed to establish safety and effectiveness in real-world surgical environments. LEVEL OF EVIDENCE: Level IV, scoping review.
Authors
- Brian J. Cole (ORCID: https://orcid.org/0000-0002-4006-2113)
- Logan D. Moews (ORCID: https://orcid.org/0009-0006-8119-1399)
- Michael T. Hirschmann
- Samuel A. Alfonsi
- Jorge Chahla
- Kyle N. Kunze
- Volker Musahl
Institutions
- Rush University Medical Center (US)
- University of Basel (CH)
- Freddie Mac (United States) (US)
- Kantonsspital Baselland Standort Bruderholz (CH)
Publication Details
- Journal
- Knee Surgery Sports Traumatology Arthroscopy
- Published
- 2026-06-19
- DOI
- https://doi.org/10.1002/ksa.70489
- Primary Topic
- Total Knee Arthroplasty Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00