Experimental Research on the Influence of the Thickness Change in the Air Interlayer Between Double-Layer Graphite Polystyrene Boards on the Energy-Saving Effect of Buildings in the Central Plains of China

While double-layer insulation structures are widely adopted, their thermal performance is critically dependent on the thermophysical behavior of the interstitial air cavity, a variable often oversimplified in current design practices. This article moves beyond generic material descriptions to investigate the specific mechanism of heat transfer transition within sealed air gaps sandwiched between graphite polystyrene boards. The innovation of this experiment lies in the rigorous isolation of air gap thickness as the primary independent variable within a 1 × 1 × 1 m closed building model, instrumented with high-precision GPRS temperature and humidity sensors to capture real-time thermal gradients under the authentic climate conditions of Anyang, Henan. The results demonstrate a non-monotonic relationship between gap thickness and effective thermal resistance, governed by the competition between molecular conduction and buoyancy-driven natural convection. Specifically, the data validates that a 20 mm air gap represents the statistically significant optimum, thereby maximizing insulation efficiency while minimizing radiative heat loss. Using this optimized structure reduces steady-state heat flux compared to monolithic equivalents and aligns with the energy conservation target. Unlike previous studies limited by simulation assumptions or short-term testing, this research provides empirically verified, long-term field data that bridges the gap between theoretical fluid dynamics and practical building envelope engineering. These findings offer a robust, physics-based reference for optimizing double-layer insulation systems in the Central Plains, directly supporting the low-carbon retrofitting of existing building stocks.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-06-18
DOI
https://doi.org/10.3390/buildings16122435
Primary Topic
Aerogels and thermal insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Research on the Influence of the Thickness Change in the Air Interlayer Between Double-Layer Graphite Polystyrene Boards on the Energy-Saving Effect of Buildings in the Central Plains of China

Wentao Liu, Qingbo Hu
Buildings
Aerogels and thermal insulation
article

Experimental Research on the Influence of the Thickness Change in the Air Interlayer Between Double-Layer Graphite Polystyrene Boards on the Energy-Saving Effect of Buildings in the Central Plains of China

Wentao Liu, Qingbo Hu
article en

Abstract

While double-layer insulation structures are widely adopted, their thermal performance is critically dependent on the thermophysical behavior of the interstitial air cavity, a variable often oversimplified in current design practices. This article moves beyond generic material descriptions to investigate the specific mechanism of heat transfer transition within sealed air gaps sandwiched between graphite polystyrene boards. The innovation of this experiment lies in the rigorous isolation of air gap thickness as the primary independent variable within a 1 × 1 × 1 m closed building model, instrumented with high-precision GPRS temperature and humidity sensors to capture real-time thermal gradients under the authentic climate conditions of Anyang, Henan. The results demonstrate a non-monotonic relationship between gap thickness and effective thermal resistance, governed by the competition between molecular conduction and buoyancy-driven natural convection. Specifically, the data validates that a 20 mm air gap represents the statistically significant optimum, thereby maximizing insulation efficiency while minimizing radiative heat loss. Using this optimized structure reduces steady-state heat flux compared to monolithic equivalents and aligns with the energy conservation target. Unlike previous studies limited by simulation assumptions or short-term testing, this research provides empirically verified, long-term field data that bridges the gap between theoretical fluid dynamics and practical building envelope engineering. These findings offer a robust, physics-based reference for optimizing double-layer insulation systems in the Central Plains, directly supporting the low-carbon retrofitting of existing building stocks.

BuildingsVol. 16(12)
Anyang Normal University (CN)
Climate action
Openalex Percentile: Top 11%
Aerogels and thermal insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Research on the Influence of the Thickness Change in the Air Interlayer Between Double-Layer Graphite Polystyrene Boards on the Energy-Saving Effect of Buildings in the Central Plains of China — Wentao Liu, Qingbo Hu · Buildings (2026) | TGRS Research Map | TGRS