Simultaneous <i>T</i> <sub>2</sub> , <i>T</i> <sub>2</sub> *, and <i>R</i> <sub>2</sub> ′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial <scp>RARE</scp> ‐ <scp>EPI MRI</scp>

ABSTRACT Purpose To demonstrate the synergy of undersampled radial 2in1‐RARE‐EPI acquisition and nonlinear model‐based reconstruction for accelerated and simultaneous T 2 , T 2 *, and R 2 ′ mapping in brains of patients with multiple sclerosis (MS). Methods 2in1‐RARE‐EPI combines a RARE module with an EPI module to capture T 2 and T 2 * information. Nonlinear model‐based reconstruction was applied to estimate T 2 , T 2 * maps directly from undersampled k ‐space data. A retrospective undersampling experiment was conducted to compare nonlinear model‐based and parallel imaging compressed sensing (PICS) reconstruction. The proposed approach was validated and compared to reference methods multiecho spin‐echo ( T 2 , MSE) and multiecho gradient‐echo ( T 2 *, MGRE) in a phantom, healthy subjects, and MS patients. Results 2in1‐RARE‐EPI together with nonlinear model‐based reconstruction enabled T 2 , T 2 *, and R 2 ′ mapping with 7.5‐fold scan‐time acceleration relative to the references, while addressing key limitations of reference techniques, including long acquisition times, misregistration, motion and off‐resonance sensitivity, and the need for calibration scans. Phantom and in vivo validation showed that the parametric maps obtained with this approach were in agreement with the reference methods. Compared with PICS, nonlinear model‐based reconstruction showed more consistent spatial detail and accuracy at higher acceleration factors. The proposed method detected small focal lesions in T 2 , T 2 *, and R 2 ′ maps of MS patients and enabled visualization of the central vein sign. Conclusion Scan time reduction facilitated by nonlinear model‐based reconstruction of 2in1‐RARE‐EPI provides a technical foundation for enhanced patient compliance, and is a fundamental precursor for broader clinical studies on the potential of T 2 , T 2 *, and R 2 ′ as imaging biomarkers.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-06-18
DOI
https://doi.org/10.1002/mrm.70465
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous T 2 , T 2 *, and R 2 ′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE ‐ EPI MRI

Sonia Waiczies, Carl Herrmann, Georg Rose, Beate Endemann et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Simultaneous T 2 , T 2 *, and R 2 ′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE ‐ EPI MRI

Sonia Waiczies, Carl Herrmann, Georg Rose, Beate Endemann, Thomas Gladytz, Jason Michael Millward, Friedemann Paul, Min‐Chi Ku, Joseph Kuchling, Franz Schmitt, Hoby P. Hetherington, Thoralf Niendorf, Hendrik Mattern, Shahriar Shalikar, Xiaoqing Wang, Jose Raul Velasquez Vides, Igor Fabian Tellez Ceja
article en

Abstract

ABSTRACT Purpose To demonstrate the synergy of undersampled radial 2in1‐RARE‐EPI acquisition and nonlinear model‐based reconstruction for accelerated and simultaneous T 2 , T 2 *, and R 2 ′ mapping in brains of patients with multiple sclerosis (MS). Methods 2in1‐RARE‐EPI combines a RARE module with an EPI module to capture T 2 and T 2 * information. Nonlinear model‐based reconstruction was applied to estimate T 2 , T 2 * maps directly from undersampled k ‐space data. A retrospective undersampling experiment was conducted to compare nonlinear model‐based and parallel imaging compressed sensing (PICS) reconstruction. The proposed approach was validated and compared to reference methods multiecho spin‐echo ( T 2 , MSE) and multiecho gradient‐echo ( T 2 *, MGRE) in a phantom, healthy subjects, and MS patients. Results 2in1‐RARE‐EPI together with nonlinear model‐based reconstruction enabled T 2 , T 2 *, and R 2 ′ mapping with 7.5‐fold scan‐time acceleration relative to the references, while addressing key limitations of reference techniques, including long acquisition times, misregistration, motion and off‐resonance sensitivity, and the need for calibration scans. Phantom and in vivo validation showed that the parametric maps obtained with this approach were in agreement with the reference methods. Compared with PICS, nonlinear model‐based reconstruction showed more consistent spatial detail and accuracy at higher acceleration factors. The proposed method detected small focal lesions in T 2 , T 2 *, and R 2 ′ maps of MS patients and enabled visualization of the central vein sign. Conclusion Scan time reduction facilitated by nonlinear model‐based reconstruction of 2in1‐RARE‐EPI provides a technical foundation for enhanced patient compliance, and is a fundamental precursor for broader clinical studies on the potential of T 2 , T 2 *, and R 2 ′ as imaging biomarkers.

Magnetic Resonance in Medicine
Boston Children's Hospital (US), Harvard University (US), Max Delbrück Center (DE), German Center for Neurodegenerative Diseases (DE), Humboldt-Universität zu Berlin (DE), ProterixBio (United States) (US), Center for Behavioral Brain Sciences (DE), Charité - Universitätsmedizin Berlin (DE), Otto-von-Guericke-Universität Magdeburg (DE)
Openalex Percentile: Top 6%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.