Development of a portable device for the detection of anti-PEG antibodies in human plasma

The conjugation of biological drugs with polyethylenglycole is widely used to reduce their immunogenicity, thereby enhancing the safety and efficacy of the drugs. For instance, some extended half-life drugs for hemophilia A patients are PEGylated FVIII products. Unfortunately, it was observed that PEG itself, whether derived from PEGylated drugs or present in everyday products (such as cosmetics or medical devices) may induce the production of anti-PEG antibodies, resulting in hypersensitivity reactions and/or loss of efficacy of PEGylated drugs. There is therefore a demand for cost-effective and rapid point-of-care (POC) measurements. To this end, a POC device based on the principle of surface plasmon resonance (SPR) is here presented. The sensor chip is functionalized directly with PEG chains via thiol chemistry and inserted into a holder manufactured in 3D printing technology. The functionalization process has been optimized to recognize anti-PEG antibodies (both IgG and IgM isotypes) and characterized using X-ray Photoelectron Spectroscopy and contact angle measurements. Dose–response curves were obtained using commercially available antibodies, both in buffer solution and in diluted human serum, achieving a limit of detection in the nanomolar range. The reusability of the optical chip was also evaluated and, as proof of concept, plasma from control subjects and hemophilia A patients treated with PEGylated FVIII were measured, comparing the results with standard techniques such as a commercial SPR instrument and an enzyme-linked immunosorbent assay. The results were obtained within 15 min from tenfold diluted human plasma, paving the way for an easy-to-use, small-sized, portable, and low-cost POC device capable of detecting anti-PEG antibodies.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-18
DOI
https://doi.org/10.1038/s41598-026-58122-9
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a portable device for the detection of anti-PEG antibodies in human plasma

Chiara Suffritti, Marco Gobbi, R. Canteri, Lucia Schiavone et al.
Scientific Reports
Protein purification and stability
article

Development of a portable device for the detection of anti-PEG antibodies in human plasma

Chiara Suffritti, Marco Gobbi, R. Canteri, Lucia Schiavone, Marten Beeg, Luigi Zeni, Nunzio Cennamo, Laura Pasquardini, Ines Tavoletta, Luca Pasquale Renzullo, Carla Valsecchi, Roberta Gualtierotti, Lia Vanzetti, Camilla Rossi, Flora Peyvandi
article en

Abstract

The conjugation of biological drugs with polyethylenglycole is widely used to reduce their immunogenicity, thereby enhancing the safety and efficacy of the drugs. For instance, some extended half-life drugs for hemophilia A patients are PEGylated FVIII products. Unfortunately, it was observed that PEG itself, whether derived from PEGylated drugs or present in everyday products (such as cosmetics or medical devices) may induce the production of anti-PEG antibodies, resulting in hypersensitivity reactions and/or loss of efficacy of PEGylated drugs. There is therefore a demand for cost-effective and rapid point-of-care (POC) measurements. To this end, a POC device based on the principle of surface plasmon resonance (SPR) is here presented. The sensor chip is functionalized directly with PEG chains via thiol chemistry and inserted into a holder manufactured in 3D printing technology. The functionalization process has been optimized to recognize anti-PEG antibodies (both IgG and IgM isotypes) and characterized using X-ray Photoelectron Spectroscopy and contact angle measurements. Dose–response curves were obtained using commercially available antibodies, both in buffer solution and in diluted human serum, achieving a limit of detection in the nanomolar range. The reusability of the optical chip was also evaluated and, as proof of concept, plasma from control subjects and hemophilia A patients treated with PEGylated FVIII were measured, comparing the results with standard techniques such as a commercial SPR instrument and an enzyme-linked immunosorbent assay. The results were obtained within 15 min from tenfold diluted human plasma, paving the way for an easy-to-use, small-sized, portable, and low-cost POC device capable of detecting anti-PEG antibodies.

Scientific Reports
University of Milan (IT), University of Trento (IT), Mario Negri Institute for Pharmacological Research (IT), University of Campania "Luigi Vanvitelli" (IT), Fondazione Bruno Kessler (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT)
Openalex Percentile: Top 10%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.