Adverse events and device malfunctions in robotic thyroidectomy: a decade-long analysis of the MAUDE database

Robotic thyroidectomy (RT) has gained increasing patient interest and clinical adoption in recent years. However, device-related adverse events and malfunctions remain poorly characterized. A review of the Manufacturer and User Facility Device Experience (MAUDE) database was conducted using the keyword "robotic thyroidectomy" between January 2016 and December 2025. Eligible reports were manually reviewed and classified by malfunctioning domain, intraoperative management, clinical consequence, procedural outcome, post-event manufacturer evaluation, and reporting timeliness. Thirty-two reports were included, and all events occurred intraoperatively. Adjunct energy device accounted for the majority of reports (68.8%), followed by robotic system (25.0%) and access/interface component (6.3%). The most frequently described event pattern was fragment/breakage. Device/component exchange (56.3%) and fragment retrieval/removal (46.9%) were common management measures. Despite these events, 25 procedures (78.1%) were completed robotically as planned, three (9.4%) were completed under downgraded robotic conditions and only one (3.1%) required open conversion. No severe patient injury was noted. In terms of reporting timeliness, the United States Food and Drug Administration (FDA) received 13 reports (40.6%) over 30 days after the event occurred. Meanwhile, four of the 31 evaluable reports (12.9%) exceeded the manufacturer-to-FDA reporting window of 30 days. Although RT-related MAUDE reports were limited and most events appeared manageable, the associated surgical burden may include workflow disruption, repeated troubleshooting, device exchange, and downgraded robotic continuation. These findings highlight the need for RT-specific risk awareness, balanced patient counseling, operative preparedness, structured troubleshooting pathways and timely, standardized post-market surveillance.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2026-06-19
DOI
https://doi.org/10.1007/s11701-026-03557-5
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adverse events and device malfunctions in robotic thyroidectomy: a decade-long analysis of the MAUDE database

Qixian Lin, Zheng Ding, Ling Zhan, Bojun Song et al.
Journal of Robotic Surgery
Thyroid and Parathyroid Surgery
article

Adverse events and device malfunctions in robotic thyroidectomy: a decade-long analysis of the MAUDE database

Qixian Lin, Zheng Ding, Ling Zhan, Bojun Song, Xianzhao Deng, Youben Fan, Bomin Guo, Zihan Lin, Lingzi Pan, Zhonghui Wu, Bo Wu, Zhihong Wang
article en

Abstract

Robotic thyroidectomy (RT) has gained increasing patient interest and clinical adoption in recent years. However, device-related adverse events and malfunctions remain poorly characterized. A review of the Manufacturer and User Facility Device Experience (MAUDE) database was conducted using the keyword "robotic thyroidectomy" between January 2016 and December 2025. Eligible reports were manually reviewed and classified by malfunctioning domain, intraoperative management, clinical consequence, procedural outcome, post-event manufacturer evaluation, and reporting timeliness. Thirty-two reports were included, and all events occurred intraoperatively. Adjunct energy device accounted for the majority of reports (68.8%), followed by robotic system (25.0%) and access/interface component (6.3%). The most frequently described event pattern was fragment/breakage. Device/component exchange (56.3%) and fragment retrieval/removal (46.9%) were common management measures. Despite these events, 25 procedures (78.1%) were completed robotically as planned, three (9.4%) were completed under downgraded robotic conditions and only one (3.1%) required open conversion. No severe patient injury was noted. In terms of reporting timeliness, the United States Food and Drug Administration (FDA) received 13 reports (40.6%) over 30 days after the event occurred. Meanwhile, four of the 31 evaluable reports (12.9%) exceeded the manufacturer-to-FDA reporting window of 30 days. Although RT-related MAUDE reports were limited and most events appeared manageable, the associated surgical burden may include workflow disruption, repeated troubleshooting, device exchange, and downgraded robotic continuation. These findings highlight the need for RT-specific risk awareness, balanced patient counseling, operative preparedness, structured troubleshooting pathways and timely, standardized post-market surveillance.

Journal of Robotic SurgeryVol. 20(1)
Shanghai Jiao Tong University (CN), Ruijin Hospital (CN), Shanghai Ninth People's Hospital (CN), Shanghai Sixth People's Hospital (CN)
Zero hunger
Openalex Percentile: Top 6%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.