Anomaly Detection in Wind Turbines: Persistence-Based Alarm Confirmation for False-Alarm Mitigation and Detection-Latency Trade-Offs

Anomaly detection models trained exclusively on healthy data are widely used in wind turbine condition monitoring because failure data are scarce, heterogeneous, and often unavailable. However, these models produce anomaly indicators that are sensitive not only to fault-related degradation but also to normal operational variability, transient disturbances, and changes in loading conditions. As a result, the practical behavior of an alarm system depends not only on the anomaly detection model but also on the decision rule used to activate and maintain alarm states. This study presents a decision-oriented evaluation of persistence-based alarm confirmation in wind turbine anomaly detection. Four representative techniques are analyzed within a unified framework: Isolation Forest, One-Class Support Vector Machine, Referenced Moving Window Principal Component Analysis using Q-statistic and percentage component weight indicators, and Autoencoder-based reconstruction error. The evaluation combines controlled OpenFAST simulations of rotor unbalance under different severity and noise conditions with an industrial SCADA case study involving a documented main bearing fault. Results show that temporal persistence strongly shapes alarm outcomes across methods and datasets. Low persistence values favor early detection but promote alarms from isolated threshold exceedances, whereas moderate persistence substantially reduces false positives while preserving detection capability in severe and well-observable faults. Excessive persistence increases detection latency and missed detections, particularly for weak, intermittent, or slowly evolving fault signatures. These findings indicate that persistence-based alarm confirmation should be treated as an explicit decision-level configuration variable, rather than as a fixed post-processing or alarm-state heuristic, when designing anomaly detection systems for wind turbine condition monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-06-19
DOI
https://doi.org/10.3390/s26123896
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anomaly Detection in Wind Turbines: Persistence-Based Alarm Confirmation for False-Alarm Mitigation and Detection-Latency Trade-Offs

Gilberto Francisco Martha de Souza, Demetrio C. Zachariadis, Miguel Ângelo de Carvalho Michalski, Arthur Henrique de Andrade Melani et al.
Sensors
Machine Fault Diagnosis Techniques
article

Anomaly Detection in Wind Turbines: Persistence-Based Alarm Confirmation for False-Alarm Mitigation and Detection-Latency Trade-Offs

Gilberto Francisco Martha de Souza, Demetrio C. Zachariadis, Miguel Ângelo de Carvalho Michalski, Arthur Henrique de Andrade Melani, Welker Facchini Nogueira, Luiz David Ricarte de Souza Custodio
article en

Abstract

Anomaly detection models trained exclusively on healthy data are widely used in wind turbine condition monitoring because failure data are scarce, heterogeneous, and often unavailable. However, these models produce anomaly indicators that are sensitive not only to fault-related degradation but also to normal operational variability, transient disturbances, and changes in loading conditions. As a result, the practical behavior of an alarm system depends not only on the anomaly detection model but also on the decision rule used to activate and maintain alarm states. This study presents a decision-oriented evaluation of persistence-based alarm confirmation in wind turbine anomaly detection. Four representative techniques are analyzed within a unified framework: Isolation Forest, One-Class Support Vector Machine, Referenced Moving Window Principal Component Analysis using Q-statistic and percentage component weight indicators, and Autoencoder-based reconstruction error. The evaluation combines controlled OpenFAST simulations of rotor unbalance under different severity and noise conditions with an industrial SCADA case study involving a documented main bearing fault. Results show that temporal persistence strongly shapes alarm outcomes across methods and datasets. Low persistence values favor early detection but promote alarms from isolated threshold exceedances, whereas moderate persistence substantially reduces false positives while preserving detection capability in severe and well-observable faults. Excessive persistence increases detection latency and missed detections, particularly for weak, intermittent, or slowly evolving fault signatures. These findings indicate that persistence-based alarm confirmation should be treated as an explicit decision-level configuration variable, rather than as a fixed post-processing or alarm-state heuristic, when designing anomaly detection systems for wind turbine condition monitoring.

SensorsVol. 26(12)
Universidade de São Paulo (BR), Universidade Cidade de São Paulo (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Apoio à Universidade de São Paulo
Affordable and clean energy
Openalex Percentile: Top 8%
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.