Graph-Based Framework with Waveform-Informed Connectivity for Multi-Label Partial Discharge Source-Type Classification

Partial discharge (PD) source-type classification is essential for condition-based maintenance of high-voltage apparatus. Existing approaches based on grid discretizations of phase-resolved partial discharge (PRPD) patterns suffer from performance degradation under stochastic interference and multi-source conditions. This paper proposes a graph-based framework that integrates the morphological characterization of raw high-frequency PD waveforms with the phase-amplitude position of individual discharge events to enable multi-label classification, identifying multiple PD sources coexisting within a single test. The framework operates through three stages: a multi-task neural network extracts per-pulse embeddings and confidence scores; a construction procedure establishes selective graph connectivity based on spatial proximity and morphological similarity; and an edge-conditioned graph neural network performs classification via message passing weighted by multimodal edge attributes. Experimental evaluation on PD measurements acquired in accordance with IEC 60270 shows that the proposed framework achieves a Matthews correlation coefficient (MCC) of 0.98 and an exact match ratio of 0.97 across single-source, noisy, and multi-source conditions, substantially outperforming histogram- and set-based baselines. The framework maintains an MCC of 0.97 in multi-source scenarios, where its advantage over existing methods is most pronounced. Cross-domain evaluation on an independent dataset acquired with different laboratory equipment confirms the approach’s robustness, achieving an MCC of 0.93 without retraining. Finally, an ablation study demonstrates that the joint removal of morphological similarity filtering and confidence-based node filtering and edge gating reduces the MCC by 0.25, confirming the critical role of the waveform-informed relational structure.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-06-19
DOI
https://doi.org/10.3390/s26123903
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Graph-Based Framework with Waveform-Informed Connectivity for Multi-Label Partial Discharge Source-Type Classification

Lorenço Santos Vasconcelos, Andreia Domingos, Fabrício Augusto Matheus Moura, Leandro Duarte et al.
Sensors
High voltage insulation and dielectric phenomena
article

Graph-Based Framework with Waveform-Informed Connectivity for Multi-Label Partial Discharge Source-Type Classification

Lorenço Santos Vasconcelos, Andreia Domingos, Fabrício Augusto Matheus Moura, Leandro Duarte, Fernando Elias de Freitas Fadel, Alan Petrônio Pinheiro, Patrícia Naomi Sakai
article en

Abstract

Partial discharge (PD) source-type classification is essential for condition-based maintenance of high-voltage apparatus. Existing approaches based on grid discretizations of phase-resolved partial discharge (PRPD) patterns suffer from performance degradation under stochastic interference and multi-source conditions. This paper proposes a graph-based framework that integrates the morphological characterization of raw high-frequency PD waveforms with the phase-amplitude position of individual discharge events to enable multi-label classification, identifying multiple PD sources coexisting within a single test. The framework operates through three stages: a multi-task neural network extracts per-pulse embeddings and confidence scores; a construction procedure establishes selective graph connectivity based on spatial proximity and morphological similarity; and an edge-conditioned graph neural network performs classification via message passing weighted by multimodal edge attributes. Experimental evaluation on PD measurements acquired in accordance with IEC 60270 shows that the proposed framework achieves a Matthews correlation coefficient (MCC) of 0.98 and an exact match ratio of 0.97 across single-source, noisy, and multi-source conditions, substantially outperforming histogram- and set-based baselines. The framework maintains an MCC of 0.97 in multi-source scenarios, where its advantage over existing methods is most pronounced. Cross-domain evaluation on an independent dataset acquired with different laboratory equipment confirms the approach’s robustness, achieving an MCC of 0.93 without retraining. Finally, an ablation study demonstrates that the joint removal of morphological similarity filtering and confidence-based node filtering and edge gating reduces the MCC by 0.25, confirming the critical role of the waveform-informed relational structure.

SensorsVol. 26(12)
Petrobras (Brazil) (BR), Universidade Federal de Uberlândia (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Petrobras, Agência Nacional de Energia Elétrica
Openalex Percentile: Top 15%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.