Improvement of uncorrected visual acuity and contrast sensitivity using Aurovue Vivid Continuous Focus Vision (CFV) lens in cataract patients at RSCM Kirana

Abstract Background The primary goal of cataract surgery has evolved beyond visual restoration toward comprehensive refractive outcomes. In aging yet functionally active populations such as Indonesia, access to premium multifocal intraocular lenses (IOLs) remains limited, creating demand for cost-effective extended-depth-of-focus (EDOF) alternatives. Objective To evaluate visual performance, contrast sensitivity, defocus profile, IOL stability, and patient-reported outcomes following implantation of the Aurovue Vivid Continuous Focus Vision (CFV) IOL developed by Aurolab. Methods This prospective interventional study included 25 eyes undergoing phacoemulsification with Aurovue ® Vivid CFV implantation. Assessments at baseline and postoperative days 1, 7, and 30 included uncorrected distance (UCDVA), intermediate (UCIVA), and near (UCNVA) visual acuity, binocular defocus curve, photopic contrast sensitivity, ultrasound biomicroscopy for tilt/decentration, and patient satisfaction. Results All eyes completed follow-up. Statistically significant improvements were observed: UCDVA from 1.06 ± 0.49 to 0.06 ± 0.11 logMAR (p < 0.001), UCIVA from 0.97 ± 0.41 to 0.19 ± 0.12 logMAR (p < 0.001), UCNVA from 1.06 ± 0.50 to 0.34 ± 0.14 logMAR (p < 0.001), and photopic contrast sensitivity from 1.20 ± 0.26 to 1.68 ± 0.14 log units (p < 0.001). The defocus curve showed maintained acuity up to approximately − 2.0 D, with a gradual decline beyond that range. IOL stability was excellent: mean tilt angles 90.30°–90.50° and median decentration 0.06 mm. Patient satisfaction reached 100% with 76% spectacle independence; mild non-functional glare was reported by 20%. No sight-threatening adverse events were recorded. Conclusion In this short-term series, the Aurovue Vivid CFV achieved satisfactory visual outcomes across all distances, with preserved contrast sensitivity, stable IOL positioning, and excellent patient-reported comfort. These data suggest the lens is a viable, cost-effective option to bridge the gap between monofocal and premium multifocal solutions in settings where access to high-end devices is constrained; longer-term, comparative studies are warranted to confirm durability and relative performance.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-08-26
DOI
https://doi.org/10.1186/s12886-026-05264-z
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Improvement of uncorrected visual acuity and contrast sensitivity using Aurovue Vivid Continuous Focus Vision (CFV) lens in cataract patients at RSCM Kirana

Jessica Zarwan, Irma Suwandi Sadikin, Syougie Ali, Faraby Martha et al.
BMC Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Improvement of uncorrected visual acuity and contrast sensitivity using Aurovue Vivid Continuous Focus Vision (CFV) lens in cataract patients at RSCM Kirana

Jessica Zarwan, Irma Suwandi Sadikin, Syougie Ali, Faraby Martha, Syska Widyawati, Rio Rhendy
article en

Abstract

Abstract Background The primary goal of cataract surgery has evolved beyond visual restoration toward comprehensive refractive outcomes. In aging yet functionally active populations such as Indonesia, access to premium multifocal intraocular lenses (IOLs) remains limited, creating demand for cost-effective extended-depth-of-focus (EDOF) alternatives. Objective To evaluate visual performance, contrast sensitivity, defocus profile, IOL stability, and patient-reported outcomes following implantation of the Aurovue Vivid Continuous Focus Vision (CFV) IOL developed by Aurolab. Methods This prospective interventional study included 25 eyes undergoing phacoemulsification with Aurovue ® Vivid CFV implantation. Assessments at baseline and postoperative days 1, 7, and 30 included uncorrected distance (UCDVA), intermediate (UCIVA), and near (UCNVA) visual acuity, binocular defocus curve, photopic contrast sensitivity, ultrasound biomicroscopy for tilt/decentration, and patient satisfaction. Results All eyes completed follow-up. Statistically significant improvements were observed: UCDVA from 1.06 ± 0.49 to 0.06 ± 0.11 logMAR (p < 0.001), UCIVA from 0.97 ± 0.41 to 0.19 ± 0.12 logMAR (p < 0.001), UCNVA from 1.06 ± 0.50 to 0.34 ± 0.14 logMAR (p < 0.001), and photopic contrast sensitivity from 1.20 ± 0.26 to 1.68 ± 0.14 log units (p < 0.001). The defocus curve showed maintained acuity up to approximately − 2.0 D, with a gradual decline beyond that range. IOL stability was excellent: mean tilt angles 90.30°–90.50° and median decentration 0.06 mm. Patient satisfaction reached 100% with 76% spectacle independence; mild non-functional glare was reported by 20%. No sight-threatening adverse events were recorded. Conclusion In this short-term series, the Aurovue Vivid CFV achieved satisfactory visual outcomes across all distances, with preserved contrast sensitivity, stable IOL positioning, and excellent patient-reported comfort. These data suggest the lens is a viable, cost-effective option to bridge the gap between monofocal and premium multifocal solutions in settings where access to high-end devices is constrained; longer-term, comparative studies are warranted to confirm durability and relative performance.

BMC OphthalmologyVol. 26(1)
University of Indonesia (ID), Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo (ID)
Openalex Percentile: Top 39%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.