Beyond the Neck: Device-Dependent Proximal Sealing After EVAR—A Propensity-Matched Comparison of AFX and Endurant

Aim: To evaluate how the guideline-defined target anticipated sealing zone (TASZ) translates into the real achieved sealing zone (RASZ), and whether this relationship is stent-graft-dependent. Methods: In a retrospective single-center study, 365 consecutive endovascular abdominal aortic aneurysm repairs (Endurant, n=267; AFX, n=98; 2011–2022) were reviewed. Preoperative and first postoperative computed tomography angiography (CTA) scans were evaluated with a previously reported centerline-driven approach. Target anticipated sealing zone and RASZ were systematically evaluated. After exclusion of patients with a TASZ shorter than 15 mm, propensity-score matching produced 75 device pairs. The primary study outcome was to evaluate the relationship between TASZ and RASZ and its dependence on stent-graft design. The neck/apposition ratio (RASZ/TASZ) was calculated to quantify the proportion of the available preoperative neck length effectively used for circumferential sealing. Linear regression assessed the independent effects of oversizing and device type on the neck-to-seal ratio. Results: After matching, AFX achieved longer RASZ than Endurant (median 34 vs 25 mm; p<0.001) and larger sealing surface (2355 vs 1862 mm 2 , p<0.001). Compared to TASZ length, Endurant showed a median shortfall of −8 mm (IQR=−20.5 to +1 mm), whereas AFX exhibited a median surplus of +2 mm (IQR=−4.5 to +11 mm; p<0.001). Regression analysis confirmed that device type, neck slope, and oversizing are independent predictors of seal utilization. Type Ia endoleak incidence was <5% without inter-device difference. Conclusions: In this retrospective analysis, despite no difference in type Ia endoleak rate, achieved proximal sealing differed between devices, with AFX more often extending beyond the traditional neck and Endurant more often not covering the entire projected neck length. Clinical Impact This study highlights that guideline-defined neck length does not uniformly translate into achieved proximal sealing across different stent-graft technologies. Quantifying the achieved sealing zone on early postoperative CTA provides additional anatomical information beyond instructions for use-based neck metrics and may help to better characterize device-specific sealing behavior.

Authors

Institutions

Publication Details

Journal
Journal of Endovascular Therapy
Published
2026-06-18
DOI
https://doi.org/10.1177/15266028261452810
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beyond the Neck: Device-Dependent Proximal Sealing After EVAR—A Propensity-Matched Comparison of AFX and Endurant

Mattia Sica, Giancarlo Accarino, Giulio Accarino, D.K. de Vries et al.
Journal of Endovascular Therapy
Aortic aneurysm repair treatments
article

Beyond the Neck: Device-Dependent Proximal Sealing After EVAR—A Propensity-Matched Comparison of AFX and Endurant

Mattia Sica, Giancarlo Accarino, Giulio Accarino, D.K. de Vries, Umberto Marcello Bracale, Enrico Cappello
article en

Abstract

Aim: To evaluate how the guideline-defined target anticipated sealing zone (TASZ) translates into the real achieved sealing zone (RASZ), and whether this relationship is stent-graft-dependent. Methods: In a retrospective single-center study, 365 consecutive endovascular abdominal aortic aneurysm repairs (Endurant, n=267; AFX, n=98; 2011–2022) were reviewed. Preoperative and first postoperative computed tomography angiography (CTA) scans were evaluated with a previously reported centerline-driven approach. Target anticipated sealing zone and RASZ were systematically evaluated. After exclusion of patients with a TASZ shorter than 15 mm, propensity-score matching produced 75 device pairs. The primary study outcome was to evaluate the relationship between TASZ and RASZ and its dependence on stent-graft design. The neck/apposition ratio (RASZ/TASZ) was calculated to quantify the proportion of the available preoperative neck length effectively used for circumferential sealing. Linear regression assessed the independent effects of oversizing and device type on the neck-to-seal ratio. Results: After matching, AFX achieved longer RASZ than Endurant (median 34 vs 25 mm; p<0.001) and larger sealing surface (2355 vs 1862 mm 2 , p<0.001). Compared to TASZ length, Endurant showed a median shortfall of −8 mm (IQR=−20.5 to +1 mm), whereas AFX exhibited a median surplus of +2 mm (IQR=−4.5 to +11 mm; p<0.001). Regression analysis confirmed that device type, neck slope, and oversizing are independent predictors of seal utilization. Type Ia endoleak incidence was <5% without inter-device difference. Conclusions: In this retrospective analysis, despite no difference in type Ia endoleak rate, achieved proximal sealing differed between devices, with AFX more often extending beyond the traditional neck and Endurant more often not covering the entire projected neck length. Clinical Impact This study highlights that guideline-defined neck length does not uniformly translate into achieved proximal sealing across different stent-graft technologies. Quantifying the achieved sealing zone on early postoperative CTA provides additional anatomical information beyond instructions for use-based neck metrics and may help to better characterize device-specific sealing behavior.

Journal of Endovascular Therapy
University of Salerno (IT), University Medical Center Groningen (NL), Istituto Neurologico Mediterraneo (IT), Federico II University Hospital (IT)
Openalex Percentile: Top 7%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.