Practicality of Using Pressure Sensors and Accelerometers to Quantify Hand Orthosis Compliance at Home

Orthosis compliance monitoring provides insights into effective orthosis design and user wear time. Frequently, patient reports of orthosis use are subjective and often result in overestimation of compliance. Therefore, a tool to objectively observe whether patients wear their orthoses as instructed is vital. This study assessed the real-world practicality of using an objective compliance monitoring device with a hand orthosis. A device consisting of a pressure sensor and accelerometer was tested by ten healthy volunteers who wore a hand orthosis daily and completed a diary of their wear time and activities for a week. Sensor data obtained from the compliance monitoring device were analysed to discern each user’s orthosis wear time. Differences between estimated wear time and actual wear time were insignificant. Pressure-based wear time estimations had a specificity of 99.3 ± 0.7% and a sensitivity of 80.3 ± 19.2%, whilst acceleration-derived estimations had a specificity of 94.5 ± 6.4% and a sensitivity of 73.2 ± 15.8%. This study demonstrated that orthosis compliance can be monitored outside the laboratory, and, furthermore, this device offers insights into the intensity and frequency of a user’s activities and has the future potential to monitor orthosis fit and forces applied to affected joints using pressure.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-06-18
DOI
https://doi.org/10.3390/bioengineering13060697
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practicality of Using Pressure Sensors and Accelerometers to Quantify Hand Orthosis Compliance at Home

Angela E. Kedgley, Matthew D. Gardiner, Devi Baruni Devanand
Bioengineering
Prosthetics and Rehabilitation Robotics
article

Practicality of Using Pressure Sensors and Accelerometers to Quantify Hand Orthosis Compliance at Home

Angela E. Kedgley, Matthew D. Gardiner, Devi Baruni Devanand
article en

Abstract

Orthosis compliance monitoring provides insights into effective orthosis design and user wear time. Frequently, patient reports of orthosis use are subjective and often result in overestimation of compliance. Therefore, a tool to objectively observe whether patients wear their orthoses as instructed is vital. This study assessed the real-world practicality of using an objective compliance monitoring device with a hand orthosis. A device consisting of a pressure sensor and accelerometer was tested by ten healthy volunteers who wore a hand orthosis daily and completed a diary of their wear time and activities for a week. Sensor data obtained from the compliance monitoring device were analysed to discern each user’s orthosis wear time. Differences between estimated wear time and actual wear time were insignificant. Pressure-based wear time estimations had a specificity of 99.3 ± 0.7% and a sensitivity of 80.3 ± 19.2%, whilst acceleration-derived estimations had a specificity of 94.5 ± 6.4% and a sensitivity of 73.2 ± 15.8%. This study demonstrated that orthosis compliance can be monitored outside the laboratory, and, furthermore, this device offers insights into the intensity and frequency of a user’s activities and has the future potential to monitor orthosis fit and forces applied to affected joints using pressure.

BioengineeringVol. 13(6)
Wexham Park Hospital (GB), Nuffield Orthopaedic Centre (GB), Frimley Health NHS Foundation Trust (GB), University of Oxford (GB), Imperial College London (GB)
Openalex Percentile: Top 12%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.